5CT1N: Difference between revisions

Jump to navigation Jump to search
mNo edit summary
(image)
Line 1: Line 1:
The '''Tektronix 5CT1N''' Curve Tracer Plug-in for the 5000 series oscilloscopes, similar to the [[7CT1N]] for the 7000 series.
The '''Tektronix 5CT1N''' Curve Tracer Plug-in for the 5000 series oscilloscopes, similar to the [[7CT1N]] for the 7000 series.


==Pictures==
<gallery>
<gallery>
Image:Tek-5ct1_in_use.jpg
Image:5440.jpg | 5Ct1N in [[5440]] mainframe vertical bay, X output connected to time base X input
Image:Tek-5ct1_in_use.jpg| Displaying transistor curves
</gallery>
</gallery>
Common Problems
 
==Common Problems==


C30 and C32 (100 &mu;F, 25 V) have a tendency to leak or short, causing associated resistors R30 and R32 (240 &Omega;, 0.25 W, 5%) to overheat and fail. A good preventative maintenance procedure would be to replace these two capacitors with modern equivalents. Two 5CT1N units purchased online had this fault, and replacement of the capacitors and resistors restored proper operation.
C30 and C32 (100 &mu;F, 25 V) have a tendency to leak or short, causing associated resistors R30 and R32 (240 &Omega;, 0.25 W, 5%) to overheat and fail. A good preventative maintenance procedure would be to replace these two capacitors with modern equivalents. Two 5CT1N units purchased online had this fault, and replacement of the capacitors and resistors restored proper operation.