36,230
edits
((no readout)) |
No edit summary |
||
(3 intermediate revisions by 2 users not shown) | |||
Line 4: | Line 4: | ||
image=5S14N-catalog75.jpg | | image=5S14N-catalog75.jpg | | ||
caption=5S14 front (catalog picture) | | caption=5S14 front (catalog picture) | | ||
introduced= | introduced=1974 | | ||
discontinued= | discontinued=1986 | | ||
series=[[5000-series scopes]]| | series=[[5000-series scopes]]| | ||
manuals= | manuals= | ||
* [[Category:Manual needed]] ''Manual needed'' ([[7S14]] may be similar enough) | * [[Category:Manual needed]] ''Manual needed'' ([[7S14]] may be similar enough) | ||
}} | }} | ||
The '''Tektronix 5S14''' is a 1 GHz dual-trace delayed sweep sampler plug-in. | The '''Tektronix 5S14''' is a 1 GHz dual-trace delayed sweep sampler plug-in. It is almost identical to the [[7S14]] plugin (from the [[7000-series scopes|7000 series]]) except for the omission of read-out circuits. | ||
It is a complete sampling system unlike, for example, the [[ | It is a complete sampling system unlike, for example, the [[7S11]], | ||
which requires a separate | which requires a separate sampling timebase plug-in to provide triggering | ||
and sampling pulse generation. | and sampling pulse generation. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec| Rise time | 350 ps (1 GHz bandwidth) }} | {{Spec| Rise time | 350 ps (1 GHz bandwidth) }} | ||
{{Spec| Trigger bandwidth | 100 MHz (Norm/Auto trigger), 1 GHz (HF sync) }} | |||
{{Spec| Vertical deflection | 2 mV/Div to 0.5 V/Div in 1—2—5 sequence }} | {{Spec| Vertical deflection | 2 mV/Div to 0.5 V/Div in 1—2—5 sequence }} | ||
{{Spec| Sweep rate | 100 µs/Div to 100 ps/Div in 1—2—5 sequence }} | {{Spec| Sweep rate | 100 µs/Div to 100 ps/Div in 1—2—5 sequence }} | ||
Line 34: | Line 35: | ||
There are two 1.35 V mercury button cells, BT1 and BT2, in the sampler circuit. | There are two 1.35 V mercury button cells, BT1 and BT2, in the sampler circuit. | ||
They act as floating bias sources, so if a 5S14 stops working it may be not defective | They act as floating bias sources, so if a 5S14 stops working it may be not defective | ||
apart from the dead batteries. | |||
The sampler used by the 5S14 is a two-diode design. | The sampler used by the 5S14 is a two-diode design. | ||
Line 44: | Line 45: | ||
==Links== | ==Links== | ||
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/sampler_7S14.htm Tek 7S14 | * [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/sampler_7S14.htm Tek 7S14 @ amplifier.cd] | ||
* http://www.barrytech.com/tektronix/tek7000/tek7s14.html | * [http://www.barrytech.com/tektronix/tek7000/tek7s14.html Tek 7S14 @ barrytech.com] | ||
==Pictures== | ==Pictures== |