67: Difference between revisions

Jump to navigation Jump to search
314 bytes added ,  20 August 2021
no edit summary
No edit summary
No edit summary
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2|
{{Plugin Sidebar  
title=Tektronix Type 67 |
|manufacturer=Tektronix
summary=Timebase plug-in |
|series=560-series scopes
image=Tek67-crop.jpg |
|type=Type 67  
caption=Type 67 front view |
|summary=Timebase plug-in  
introduced=1961 |
|image=Tek67-crop.jpg  
discontinued=(?) |
|caption=Type 67 front view  
series=[[560-series scopes]]|
|introduced=1961  
manuals=
|discontinued=(?)  
* [http://w140.com/mmm/tek-67.pdf Tektronix Type 67 Manual (PDF)]
|designers=
* [http://bama.edebris.com/download/tek/67/67.djvu Tektronix Type 67 Manual (DjVu)]
|manuals=
* [[Media:070-267.pdf|Tektronix Type 67 Manual]] (PDF)
* [http://bama.edebris.com/download/tek/67/67.djvu Tektronix Type 67 Manual @ BAMA] (DjVu)
* [[Media:Tek type 67 2B67 irb.pdf|Tektronix Type 67 and Type 2B67 Instrument Reference Book (PDF, OCR)]]
* [[Media:Tek type 67 2B67 irb.pdf|Tektronix Type 67 and Type 2B67 Instrument Reference Book (PDF, OCR)]]
}}
}}
The '''Tektronix Type 67''' is a time-base for [[560-series scopes]], providing calibrated sweep rates from 1 μs/div to 5 s/div, [[introduced in 1961]].   
The '''Tektronix Type 67''' is a time-base for [[560-series scopes]], providing calibrated sweep rates from 1 μs/div to 5 s/div, [[introduced in 1961]].   
The 67 does not have a single-sweep mode.
The unmodified 67 does not have a single-sweep mode.


It uses a [[6DJ8]] as the trigger input amplifier, followed by another [[6DJ8]] as a Schmitt trigger.
It uses a [[6DJ8]] as the trigger input amplifier, followed by another [[6DJ8]] as a Schmitt trigger.
The 67 was replaced by the [[2B67]] which is very similar but has a single-sweep mode.
The 67 was replaced by the [[2B67]] which is very similar but has a single-sweep mode.
 
==Mod 104==
 
'Mod 104' is a factory modification to the Type 67 that gives the timebase single sweep capability. It is not documented in the service manual.
 
Although it is unknown how many Type 67s were fitted with 'Mod 104', there is at least one that exists with the modification.


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Sweep Rate | 1μs/div to 5s/div }}
{{Spec | Sweep Rate | 1 μs/div to 5 s/div }}
{{Spec | Vernier Range | 1μs/div to 12s/div }}
{{Spec | Vernier Range | 1 μs/div to 12 s/div }}
{{Spec | Max. Magnification | 5x }}
{{Spec | Max. Magnification | }}
{{Spec | Triggering | Auto, Manual, Free Run }}
{{Spec | Triggering | Auto, Manual, Free Run }}
{{Spec | Ext. Input Sensitivity| 1V/div }}
{{Spec | Ext. Input Sensitivity| 1 V/div }}
{{SpecGroup | With Mod 104 }}
{{SpecGroup | With Mod 104 }}
{{Spec | Sweep Mode | Normal, Single }}
{{Spec | Sweep Mode | Normal, Single }}
{{EndSpecs}}