* [[Media:Tekscope 1975 V7 N5.pdf | TekScope Vol. 7 No. 5, 1975 p.15+: Dave McCullough, ''Delayed gate aids oscilloscope digital measurements'']]


==Operation==
==Operation==
===Delayed Sweep Gate output ===
When the delayed timebase trigger source switch is set to INT (pushed in) and the internal connector P613 is in the active position,
the DLY'D TRIG IN connector becomes a Delayed Sweep Gate output.
This is useful e.g. to connect to a [[7D15]]'s arming inputs, or a [[7D12]]/[[M2]]'s external trigger input. 
See the 1975 TekScope article linked above.
===Variable control===
===Variable control===
Through an internal jumper, the front-panel variable control (red knob) can be selected to vary either the main sweep,
Through an internal jumper, the front-panel variable control (red knob) can be selected to vary either the main sweep,
the delayed sweep or the main sweep hold-off.  
the delayed sweep or the main sweep hold-off. See the 1975 TekScope article linked above.
See i.a. [[Media:Tekscope 1975 V7 N5.pdf | TekScope Vol. 7 No. 5, 1975]] p.15+: Dave McCullough, ''Delayed gate aids oscilloscope digital measurements''.
 
===Use as Delayed Timebase ===
The 7B53A only works in "triggered after delay" mode when used as a delayed timebase, unlike e.g. the [[7B92]].


===X-Y operation===
===X-Y operation===
The 7B53 supports X-Y mode by selecting the "Ampl" position on the Time/Div switch.  
The 7B53 supports X-Y mode by selecting the "Ampl" position on the Time/Div switch.  
The X signal can be picked up from a vertical plug-in via the internal trigger path or applied via the "Main Trig In or Amp In" input,
The X signal can be picked up from a vertical plug-in via the internal trigger path or applied via the "Main Trig In or Amp In" input,
as determined by the Trigger Source switch setting. Sensitivity on the external input is 100 mV/Div,  
as determined by the Trigger Source switch setting. Sensitivity on the external input is 100 mV/Div,  
which can be increased to 10 mV/DIv by selecting the x10 magnifier, or decreased to 1 V/Div by pushing the EXT÷10 button.
which can be increased to 10 mV/DIv by selecting the x10 magnifier, or decreased to 1 V/Div by pushing the EXT÷10 button.
 
===Delayed Sweep Gate output ===
When the delayed timebase trigger source switch is set to INT (pushed in) and the internal connector P613 is in the active position,
the DLY'D TRIG IN connector becomes a Delayed Sweep Gate output.
This is useful e.g. to connect to a [[7D15]]'s arming inputs, or a [[7D12]]/[[M2]]'s external trigger input.
 
===Use as Delayed Timebase ===
The 7B53A only works in "triggered after delay" mode when used as a delayed timebase, unlike e.g. the [[7B92]].


==Prices==
==Prices==