7B53A: Difference between revisions

106 bytes added ,  13 December 2021
no edit summary
No edit summary
No edit summary
Line 1: Line 1:
{{Plugin Sidebar |
{{Plugin Sidebar
manufacturer=Tektronix | type=7B53A |
|manufacturer=Tektronix
summary=100 MHz Dual Timebase |
|series=7000-series scopes
image=Tek-7b53a-front.jpg |  
|type=7B53A  
caption=Tektronix 7B53A Timebase plug-in|
|summary=100 MHz Dual Timebase
introduced=1973 |
|image=Tek-7b53a-front.jpg
discontinued=1992 |
| caption=Tektronix 7B53A Timebase plug-in
series=7000-series scopes|
|introduced=1973
manuals=
|discontinued=1992
* [[Media:070-1342-00.pdf|7B53A/7B53AN Dual Time Base Instruction Manual]] (OCR, PDF)
|manuals=
* [http://bama.edebris.com/download/tek/7b53a/Tektronix_7B53A_Service_May88.pdf Tektronix 7B53A and 7B53AN Manual Revised May 1988 (PDF)]
* [[Media:070-1252-00.pdf|7B53A/7B53AN Dual Time Base Operators Manual]] (OCR)
* [http://w140.com/smb/7b53a_an_ops_sm.pdf Tektronix 7B53A and 7B53AN Operators Manual (OCR, PDF)]
* [[Media:070-1342-00.pdf|7B53A/7B53AN Dual Time Base Instruction Manual]] (OCR)
* [http://w140.com/smb/7b53a_an_svc_sm.pdf Tektronix 7B53A and 7B53AN Service Manual (OCR, PDF)]
* [[Media:070-1471-00.pdf|7B53A/7B53AN Option 5 (TV Sync Separator) Instruction Manual Supplement]] (OCR)
* [http://w140.com/tek_7B53A_opt_5.pdf Tektronix 7B53A and 7B53AN Option 5 TV Sync Separator Manual (PDF)]
 
<small>
'''Alternate copies'''
* [https://w140.com/smb/7b53a_an_svc_sm.pdf Tektronix 7B53A and 7B53AN Service Manual] (OCR)
* [http://bama.edebris.com/download/tek/7b53a/Tektronix_7B53A_Service_May88.pdf Tektronix 7B53A/7B53AN Manual Rev. May 1988] @ BAMA
'''Modifications'''
* [[media:7B53A MOD.pdf|7B53A and 7B53AN Custom Modifications Manual (PDF)]]
* [[media:7B53A MOD.pdf|7B53A and 7B53AN Custom Modifications Manual (PDF)]]
* [[Media:061-1570-00.pdf|7B53A and 7B53AN Mods (PDF)]]
* [[Media:061-1570-00.pdf|7B53A and 7B53AN Mods (PDF)]]
</small>
}}
}}
The '''Tektronix 7B53A''' and '''7B53AN''' is a 100 MHz dual time base plug-in for [[7000-series scopes]].
The '''Tektronix 7B53A''' is a 100 MHz dual time base plug-in for [[7000-series scopes]] that was [[introduced in 1973]] and produced until the discontinuation of the 7000 series in 1992.


It succeeded the short-lived [[7B52]], with sweep mode selection integrated into the time/Div switch, and the 7B52's combined trigger level/polarity control replaced with separate, concentric knobs.
It succeeded the short-lived [[7B52]], with sweep mode selection integrated into the time/Div switch, and the older combined trigger level/polarity control replaced with separate, concentric knobs.


The 7B53AN is electrically identical to he 7B53A but omits the circuits needed to drive the alphanumeric readout system provided in 7000-series mainframes.   
The '''7B53AN''' is identical to the 7B53A but omits the circuits needed to drive the alphanumeric readout system provided in 7000-series mainframes.   
The '''TD-1085/U''' is a military designation for the 7B53AN11 which was used in the [[AN/USM-281C]] military version of the [[7603]] scope. The '''TD-1159/U''' is another military version of the standard 7B53A with readout support.
 
The '''TD-1085/U''' is a military designation for the 7B53AN11 which was used in the [[AN/USM-281C]] military version of the [[7603]] scope.  
 
The '''TD-1159/U''' is another military version of the standard 7B53A with readout support.


There does not appear to have been a product sold called simply "7B53".  There is a 7B53N, a 7B53A, and a 7B53AN.
There does not appear to have been a product sold called simply "7B53".  There is a 7B53N, a 7B53A, and a 7B53AN.
Line 46: Line 55:
}}
}}
{{EndSpecs}}
{{EndSpecs}}
==Links==
* [[Media:Tekscope 1975 V7 N5.pdf|TekScope Vol. 7 No. 5, 1975 p.15+: Dave McCullough, ''Delayed gate aids oscilloscope digital measurements'']]
* [https://www.youtube.com/watch?v=75wUU_tc-zc Zenwizard Studios - Tektronix 7B53A Repair and Alignment]


==Operation==
==Operation==
Line 67: Line 72:
The X signal can be picked up from a vertical plug-in via the internal trigger path or applied via the "Main Trig In or Amp In" input, as determined by the Trigger Source switch setting.  
The X signal can be picked up from a vertical plug-in via the internal trigger path or applied via the "Main Trig In or Amp In" input, as determined by the Trigger Source switch setting.  
Sensitivity on the external input is 100 mV/Div, which can be increased to 10 mV/DIv by selecting the x10 magnifier, or decreased to 1 V/Div by pushing the EXT÷10 button.
Sensitivity on the external input is 100 mV/Div, which can be increased to 10 mV/DIv by selecting the x10 magnifier, or decreased to 1 V/Div by pushing the EXT÷10 button.
==Links==
* [[Media:Tekscope 1975 V7 N5.pdf|TekScope Vol. 7 No. 5, 1975 p.15+: Dave McCullough, ''Delayed gate aids oscilloscope digital measurements'']]
* [https://www.youtube.com/watch?v=75wUU_tc-zc Tektronix 7B53A Repair and Alignment] by Zenwizard Studios @ YouTube


==Prices==
==Prices==