AA501: Difference between revisions

627 bytes added ,  9 October 2023
no edit summary
No edit summary
No edit summary
 
(17 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{TM500 | mfg=Tektronix | type=AA501 | function=audio analyzer | class=filter | image=Tektronix-AA501-front.jpg | introduced=1980 | discontinued=(?) |
{{TM500 | mfg=Tektronix | type=AA501 | function=audio analyzer | class=filter | image=Tektronix-AA501-front.jpg | introduced=1980 | discontinued=(?) | an=an
manuals=*[[Media:AA501-PS501-PS503A.pdf|Tektronix PS501, PS503A, and AA501 Specifications (PDF)]]
|designers=Bruce Hofer;Rush Hood;Richard Cabot;Fred Armentrout;
|manuals=
* [[Media:070-2958-00.pdf|Tektronix AA501 Instruction Manual]]
* [[Media:070-6592-00.pdf|Tektronix AA501A Instruction Manual]]
* [[Media:AA501-PS501-PS503A.pdf|Tektronix PS501, PS503A, and AA501 Specifications]]
}}
}}
It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <−95 dB (0.0018 %). Residual THD+N is specified as <−90 dB (<0.0032 %).


It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ and unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <-95 dB (0.0018 %). Residual THD+N is specified as <-90 dB (<0.0032 %).
It was one of the first, if not the first, audio analyzers capable of fully automatic measurements without requiring manual reference level setting, range selection or frequency fine-tuning.  It is ideally combined with the [[SG505]] low distortion oscillator.
 
It was one of the first, if not the first, audio analyzer capable of fully automatic measurements without requiring manual reference level setting, range selection or frequency fine-tuning.  It is ideally combined with the [[SG505]] low distortion oscillator.


The AA501 is two slots wide.
The AA501 is two slots wide.


{{MissingSpecs}}
{{MissingSpecs}}
==Links==
* [https://www.youtube.com/watch?v=H09SmKoOVys Zenwizard Studios - AA501 Calibration and Alignment]
* [https://www.youtube.com/watch?v=85fS89rtQ3I Zenwizard Studios - AA501A Repair]
* [https://www.youtube.com/watch?v=tYgHyt5VblE Zenwizard Studios - AA501A Calibration and Alignment]
* [https://www.youtube.com/watch?v=RS4gbAgPu3o Zenwizard Studios - AA501 Troubleshooting and Repair]
* See also [[F7523A1]]
{{Documents|Link=AA501}}


==Pictures==
==Pictures==
<gallery>
<gallery>
Tek aa501 close.jpg
Tek aa501 close.jpg
Image:Tektronix-AA501-SG502.JPG|Measuring distortion of an SG502
Tektronix-AA501-SG502.JPG|Measuring distortion of an SG502
Image:Tektronix-AA501-HP239A.JPG|Measuring distortion of an HP239A
Tektronix-AA501-HP239A.JPG|Measuring distortion of an HP239A
</gallery>
</gallery>