P2220: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Complete reformat with probe template and additional info.)
No edit summary
 
(3 intermediate revisions by the same user not shown)
Line 2: Line 2:
|manufacturer=Tektronix
|manufacturer=Tektronix
|model=P2220
|model=P2220
|summary=200MHz 1x/10x Passive Probe
|summary=200 MHz 1x/10x Passive Probe
|image=Tek p2220 1.jpg
|image=Tek p2220 1.jpg
|caption=
|caption=Tektronix P2220
|for=15 and 25 pF input capacitances
|for=1 MΩ scope inputs
|series=
|series=
|introduced=?
|introduced=(?)
|discontinued=?
|discontinued=(?)
|manuals=
|manuals=
* [[Media:tek_p2220.pdf|Instruction Manual]] (PDF)
* [[Media:071-1464-00.pdf|P2220 Instruction Manual]] (PDF)
}}
}}
The '''Tektronix P2220''' is a 200 MHz passive ×1/×10 probe designed for use with Tektronix [[TDS1000]], [[TDS2000]], and TPS2000 Series oscilloscopes with input capacitances between 15 and 25 pF.  Bandwidth in ×1 mode is 6 MHz.<br>
The '''Tektronix P2220''' is a 200 MHz passive ×1/×10 probe designed for use with Tektronix [[TDS1000]], [[TDS2000]], and TPS2000 Series oscilloscopes with input capacitances between 15 and 25 pF.  Bandwidth in ×1 mode is 6 MHz.<br>
The P2220 probe also provides floating measurement capability up to 30 VRMS with TPS2000 Series oscilloscopes only.
The P2220 probe also provides floating measurement capability up to 30 VRMS with TPS2000 Series oscilloscopes only.

Latest revision as of 07:11, 25 August 2021

Tektronix P2220
200 MHz 1x/10x Passive Probe
Tektronix P2220

Compatible with 1 MΩ scope inputs

Produced from (?) to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P2220 is a 200 MHz passive ×1/×10 probe designed for use with Tektronix TDS1000, TDS2000, and TPS2000 Series oscilloscopes with input capacitances between 15 and 25 pF. Bandwidth in ×1 mode is 6 MHz.
The P2220 probe also provides floating measurement capability up to 30 VRMS with TPS2000 Series oscilloscopes only.

Specifications

10x 1x
Bandwidth DC to 200 MHz DC to 6 MHz
Probe Length 1.5 m 1.5 m
Attenuation Ratio 10:1 1:1
Compensation Range 15 to 25 pF 15 to 25 pF
Input Capacitance 17.0 pF 110 pF
Input Resistance 10 MΩ 1 MΩ
Max Input Voltage 300 V Cat II 150 V Cat II


Compatible with