P6015: Difference between revisions

352 bytes added ,  21 October 2023
no edit summary
No edit summary
No edit summary
 
(12 intermediate revisions by 3 users not shown)
Line 6: Line 6:
|caption=P6015
|caption=P6015
|for=1 MΩ scope inputs
|for=1 MΩ scope inputs
|introduced=(?)
|introduced=1963
|discontinued=(?)
|discontinued=1990
|manuals=
|manuals=
* [https://w140.com/p6015.pdf Tektronix P6015 Manual] (Copyright date 1963)
* [[Media:070-0373-01.pdf|P6015 manual 070-0373-01 (1963)]]
* [https://w140.com/P6015_070-0373-02.pdf Tektronix P6015 Manual] (Revision date 1985)
* [[Media:070-0373-02.pdf|P6015 manual 070-0373-02 (1985)]]
* [https://w140.com/P6015A_tek_original.pdf Tektronix P6015A Manual]
* [[Media:070-0373-02 rev 1990.pdf|P6015 manual 070-0373-02 (1990)]]
* [https://w140.com/tek_p6015a_mod.pdf Tektronix P6015A Manual with Schematic]
 
* [https://w140.com/tek_p6007_p6009_p6015_cat.pdf Tektronix P6007 P6009 P6015 Catalog Description]
* [[Media:Tek_p6007_p6009_p6015_cat.pdf|P6007 P6009 P6015 Catalog Description]]
}}
}}
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   


It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak).  
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the [[P6013]] predecessor model.
The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used.
The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its [[wikipedia:Montreal Protocol|ozone-depleting properties]]. For this reason, it was replaced by the [[P6015A]] [[introduced in 1991|in 1991]], which uses a silicone based replacement.


The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants, which was available with [[PL-259]] or [[BNC]] plugs on the scope side (termination box part numbers 015-039/015-0039-00 and 015-049/015-0049-00, respectively).


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Attenuation ratio  | 1000× }}
{{Spec | Bandwidth          | 75 MHz (10' cable), 25 MHz (25' cable) }}
{{Spec | Risetime          | 4.67 ns (10' cable), 14 ns (25' cable) }}
{{Spec | Attenuation       | 1000× }}
{{Spec | Input impedance    | 100 MΩ // 3 pF }}
{{Spec | Input impedance    | 100 MΩ // 3 pF }}
{{Spec | Rise time          | 4.67 ns (10' cable), 14 ns (25' cable) }}
{{Spec | Compensation range | 15-50 pF }}
{{Spec | Bandwidth          | 75 MHz (10' cable), 25 MHz (25' cable) }}
{{Spec | Compensation Range | 15-50 pF }}
{{Spec | Max. input voltage |  
{{Spec | Max. input voltage |  
* With dielectric filling: 20 kV DC or RMS to 100 kHz, pulse up to 40 kV (10%, < 0.1s)
* With dielectric filling: 20 kV DC or RMS to 100 kHz, pulse up to 40 kV (10%, < 0.1s)
Line 35: Line 35:


==Links==
==Links==
* [[Media:US3256484.pdf | US Patent 3,256,484]]
* [[Patent US 3256484A|US Patent 3,256,484; ''High voltage test probe containing a part gas, part liquid dielectric fluid under pressure and having a transparent housing section for viewing the presence of the liquid therein'']]. Paul V Terry, 1962.
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/P6015.html P6015A @ amplifier.cd]
* [http://www.barrytech.com/tektronix/probes/tekp6015.html P6015 @ barrytech.com]
* [http://www.barrytech.com/tektronix/probes/tekp6015.html P6015 @ barrytech.com]


==Pictures==
==Pictures==
<gallery>
<gallery>
Tek P6015 box.jpg | Tektronix P6015 in box
Tek P6015 box.jpg           | Tektronix P6015 in box
Tek P6015 box closed.jpg
Tek_P6015_1.jpg
Tek_P6015_1.jpg
Tek_P6015_2.jpg
Tek_P6015_2.jpg
Line 47: Line 47:
Tek_P6015_4.jpg
Tek_P6015_4.jpg
P6015 BW.png
P6015 BW.png
Tek p6015 schem.png
Tek p6015 schem.png         | schematic <br> old version
Tek P6015 derating.jpg      | Derating curves
Tek P6015 derating.jpg      | Derating curves
Tek hv dielectric fluid.jpg | Can of Freon Dielectric Fluid
P6015_Freon_Can.jpg         | Can of Freon Dielectric Fluid
Tek P6015 term box.jpg      | Termination box
Tek P6015 term box.jpg      | Termination box <br> new version
</gallery>
</gallery>


[[Category:1 MΩ Oscilloscope probes]]
[[Category:1 MΩ Oscilloscope probes]]
[[Category:High voltage oscilloscope probes]]
[[Category:High voltage oscilloscope probes]]
387