P6015: Difference between revisions

225 bytes added ,  19 July 2022
first in 1963 catalog
No edit summary
(first in 1963 catalog)
Line 6: Line 6:
|caption=P6015
|caption=P6015
|for=1 MΩ scope inputs
|for=1 MΩ scope inputs
|introduced=(?)
|introduced=1963
|discontinued=(?)
|discontinued=(?)
|manuals=
|manuals=
* [https://w140.com/p6015.pdf P6015 Instruction Manual 070-0373-01] (Copyright date 1963)
* [[Media:070-0373-01.pdf|P6015 Manual 070-0373-01]] (Copyright date 1963)
* [https://w140.com/P6015_070-0373-02.pdf P6015 Instruction Manual 070-0373-02] (Revision date 1985)
* [[Media:070-0373-02.pdf|P6015 Manual 070-0373-02]] (Revision date 1985)
* [https://w140.com/tek_p6015a_mod.pdf P6015A Manual with Schematic 070-8223-04]
* [[Media:070-8223-02.pdf|P6015A Manual 070-8223-02]]
* [https://w140.com/P6015A_tek_original.pdf P6015A Instruction Manual 070-8223-05]
* [[Media:070-8223-04.pdf|P6015A Manual 070-8223-04]] (with schematics)
* [https://w140.com/tek_p6007_p6009_p6015_cat.pdf P6007 P6009 P6015 Catalog Description]
* [[Media:070-8223-05.pdf|P6015A Manual 070-8223-05]]
* [[media:51W-8217-2.pdf|P6015A Product Brochure]]
* [[Media:Tek_p6007_p6009_p6015_cat.pdf|P6007 P6009 P6015 Catalog Description]]
* [[Media:51W-8217-2.pdf|P6015A Product Brochure]]
}}
}}
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   


It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak).  
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the [[P6013]] predecessor model.<br />The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its [[wikipedia:Montreal Protocol|ozone-depleting properties]].  
The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used.
 
In the CFC-free '''P6015A''' successor, introduced in 1991, a silicone based replacement is used.


The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.
The CFC-free '''P6015A''' successor was introduced in 1991.


{{BeginSpecs}}
{{BeginSpecs}}
Line 38: Line 38:


==Links==
==Links==
* [[Media:US3256484.pdf | US Patent 3,256,484]]
* [[Patent US 3256484A|US Patent 3,256,484; ''High voltage test probe containing a part gas, part liquid dielectric fluid under pressure and having a transparent housing section for viewing the presence of the liquid therein'']].  Paul V Terry, 1962.
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/P6015.html P6015A @ amplifier.cd]
* [https://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/P6015.html P6015A @ amplifier.cd]
* [http://www.barrytech.com/tektronix/probes/tekp6015.html P6015 @ barrytech.com]
* [http://www.barrytech.com/tektronix/probes/tekp6015.html P6015 @ barrytech.com]