Line 22: Line 22:
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   


It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the [[P6013]] predecessor model.<br />The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its [[wikipedia:Montreal Protocol|ozone-depleting properties]]. The CFC-free '''P6015A''' successor, introduced in 1991, uses a silicone based replacement.
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the [[P6013]] predecessor model.<br />The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its [[wikipedia:Montreal Protocol|ozone-depleting properties]].  


The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.
The CFC-free '''P6015A''' successor, introduced in 1991, uses a silicone based replacement. It is still available new as of 2023.
 
All versions have a compensating circuit at the scope end of the cable with multiple adjustable RC constants.  The original P6015 was available with [[PL-259]] or [[BNC]] plugs on the scope side.  The P6015A comes with a BNC plug, in versions with and without a [[readout pin]].


{{BeginSpecs}}
{{BeginSpecs}}