The P6032 is | The '''Tektronix P6032''' is an 850 MHz cathode-follower probe, intended for use with samplers such as the [[1S1]], [[3S1]], [[3S76]] and [[4S1]]. | ||
It was designed by [[Murlan Kaufman]]. | |||
There is an [[EC1000]] subminiature triode in the probe body, which is why it gets slightly warm during operation. | |||
Like all active probes, the P6032 requires power, and for this reason it has two connectors at the scope end of cable. | |||
There is a four-pin power connector and a 50 Ω [[GR-874 connector]] for the signal. | |||
The triode has limited dynamic range, so attenuator attachments are provided that attach to the tip of the probe. | |||
These attenuators also reduce the loading of the probe on the probed circuit. | |||
What, exactly, does the clipping line in the probe body do? | |||
It appears to be 21 mm of RG-174 cable connected to the triode's cathode at one end, and open at the other end. | |||
The circuit description in the manual describes it vaguely, saying only that, "The clipping line reduces signal aberration to a minimum." | |||
==Manuals== | |||
* [[Media:070-327.pdf|Tektronix P6032 Manual (PDF)]] / [http://w140.com/kurt/p6032.djvu (DjVu)] | |||
* [[Media:Tek_P6032_preliminary_manual_1962.pdf|Tektronix P6032 Preliminary Manual (PDF)]] | |||
==Pictures== | |||
<gallery> | <gallery> | ||
P6032_ext.jpg|External view of P6032 without attenuator attachment. | |||
P6032-schematic.png|P6032 Schematic | |||
P6032_int_c.jpg|Internal view of P6032 Probe tip connects directly to triode grid, which is a bare wire coming out of the top of the tube. Clipping line runs along the body of the probe to the left of the tube socket. | |||
P6032x10.jpg | ×20 attenuator tip | |||
P6032_pwr.jpg|Internal view of power supply at end of P6032 cable. Signal coax passes through undisturbed. | |||
P6032_risetime.jpg|Display on [[545|545A]] with 1S1 and P6032. Pulse is generated by Tek [[284]] tunnel diode pulser driving into 50 ohm load, GR-BNC adaptor and then to the probe using a probe to BNC adaptor. The 10x attenuator tip was used on the P6032. Timebase is 200ps/div. | |||
Tek p6032 kit 1.jpg | |||
Tek p6032 kit 2.jpg | |||
Tek p6032 kit 3.jpg | |||
Tek p6032 kit 4.jpg | |||
</gallery> | </gallery> | ||
[[Category:Active oscilloscope probes]] |