Line 7: | Line 7: | ||
|for=50 Ω scope inputs | |for=50 Ω scope inputs | ||
|introduced=1968 | |introduced=1968 | ||
|discontinued= | |discontinued=1992 | ||
|designers=Glenn Bateman | |||
|manuals= | |manuals= | ||
There are three versions of the manual: | There are three versions of the manual: | ||
Line 14: | Line 15: | ||
* [[Media:070-7129-01.pdf|070-7129-01 - 1992]] | * [[Media:070-7129-01.pdf|070-7129-01 - 1992]] | ||
* [[Media:P6046 Voltage and Waveform Information.pdf|P6046 Voltage and Waveform Information | * [[Media:P6046 Voltage and Waveform Information.pdf|P6046 Voltage and Waveform Information]] | ||
* [[Media:P6046 Schematics Rev. C June 1977 11x17.pdf|P6046 Schematics Rev. C June 1977 | * [[Media:P6046 Schematics Rev. C June 1977 11x17.pdf|P6046 Schematics Rev. C June 1977]] | ||
* [[Media:Tek p6046 eis signature page.pdf|P6046 Engineering Instrument Specification Signature Page]] | |||
* [[Media:Tek p6046 eis signature page.pdf|P6046 Engineering Instrument Specification Signature Page | |||
* [[Media:Tek p6046 fcp march 1968.pdf|P6046 Factory Calibration Procedure, March 1968]] | * [[Media:Tek p6046 fcp march 1968.pdf|P6046 Factory Calibration Procedure, March 1968]] | ||
}} | }} | ||
The '''Tektronix P6046''' is a 100 MHz differential probe oscilloscope probe [[introduced in 1968]]. | The '''Tektronix P6046''' is a 100 MHz differential probe oscilloscope probe [[introduced in 1968]] and discontinued sometime after 1992. | ||
It was designed by [[Glenn Bateman]]. | It was designed by [[Glenn Bateman]]. | ||
Line 30: | Line 28: | ||
A separate amplifier (015-0106-00) was available as an option to use the probe on a 50 Ω input scope set at 10 mV/Div. | A separate amplifier (015-0106-00) was available as an option to use the probe on a 50 Ω input scope set at 10 mV/Div. | ||
An additional ×10 attenuator (010-0361-00) can be plugged onto the P6046's inputs. | |||
Note that the probe itself acts as either a 1× or 10× attenuation probe dependent on a signal voltage on pin D of the connector. | Note that the probe itself acts as either a 1× or 10× attenuation probe dependent on a signal voltage on pin D of the connector. | ||
When used with the amplifier, 10× mode is used in the 200, 100, and 50 mV/div settings and 1× mode for 20, 10, 5, 2, and 1 mV/div. | When used with the amplifier, 10× mode is used in the 200, 100, and 50 mV/div settings and 1× mode for 20, 10, 5, 2, and 1 mV/div. | ||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | 45 MHz with 1A5; 100 MHz with amplifier; AC low frequency cut-off 20 Hz (2 Hz with ×10 head) }} | |||
{{Spec | Input impedance | 1 MΩ // 10 pF (with ×10 head, 10 MΩ // 3 pF) }} | |||
{{Spec | Common-mode range | ±5 V DC+peak AC up to 10 MHz, decreasing to ±2 V at 50 MHz }} | |||
{{Spec | Maximum Allowable Input | 25 V total DC+peak AC, 25 V total difference between + and − input tips }} | |||
{{EndSpecs}} | |||
==Operation== | ==Operation== | ||
Line 45: | Line 50: | ||
==Links== | ==Links== | ||
* [http://www.i9t.net/p6046/p6046.html P6046 @ iceNINE Tech] | * [http://www.i9t.net/p6046/p6046.html P6046 @ iceNINE Tech] | ||
* [ | * [https://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/P6046.htm P6046 @ amplifier.cd] | ||
{{Documents|Link=P6046}} | |||
==Pictures== | ==Pictures== |