P6056: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(4 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
[[File:P6056.jpg|thumb|350px|right|P6056 probe]] | |||
The '''Tektronix P6056''' is a 3.5 GHz ×10 probe for 50 Ω-input scopes, released along with the [[7A19]] amplifier in 1972. | The '''Tektronix P6056''' is a 3.5 GHz ×10 probe for 50 Ω-input scopes, released along with the [[7A19]] amplifier in 1972. | ||
Line 5: | Line 6: | ||
Its sister model [[P6057]] has ×100 attenuation. | Its sister model [[P6057]] has ×100 attenuation. | ||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | DC to 3.5 GHz }} | |||
{{Spec | Rise time | 100 ps }} | |||
{{Spec | Attenuation | 10× }} | |||
{{Spec | Input impedance | 500 Ω // approx. 1 pF }} | |||
{{Spec | Scope Input | 50 Ω }} | |||
{{Spec | Features | Readout Pin, ID Button }} | |||
{{EndSpecs}} | |||
==Manual== | ==Manual== | ||
* [ | * [https://w140.com/tek_P6056_P6057.pdf Tektronix P6056 and P6057 Manual (PDF)] | ||
<blockquote> | |||
<u>WARNING</u>: | |||
This high performance device has a fragile resistor assembly in the<br /> | |||
probe head, subject to failure in rough usage. Use with slip-on tip<br /> | |||
whenever possible. One replacement part is provided with the package.<br /> | |||
Contact nearest Field Office for additional parts (P/N 307-0330-00), if<br /> | |||
required. For replacement and Calibration Procedure, refer to Pg. 3 & 4<br /> | |||
of manual. | |||
</blockquote> | |||
[[Category:50 | [[Category:50 Ω Oscilloscope probes]] | ||
[[Category:Introduced in 1972]] | [[Category:Introduced in 1972]] |
Revision as of 14:07, 23 January 2021
The Tektronix P6056 is a 3.5 GHz ×10 probe for 50 Ω-input scopes, released along with the 7A19 amplifier in 1972.
It has an Identify switch and readout contact.
Its sister model P6057 has ×100 attenuation.
Key Specifications
Bandwidth | DC to 3.5 GHz |
---|---|
Rise time | 100 ps |
Attenuation | 10× |
Input impedance | 500 Ω // approx. 1 pF |
Scope Input | 50 Ω |
Features | Readout Pin, ID Button |
Manual
WARNING:
This high performance device has a fragile resistor assembly in the
probe head, subject to failure in rough usage. Use with slip-on tip
whenever possible. One replacement part is provided with the package.
Contact nearest Field Office for additional parts (P/N 307-0330-00), if
required. For replacement and Calibration Procedure, refer to Pg. 3 & 4
of manual.