The '''Tektronix P6207''' is an active 10× FET probe with a [[Tekprobe SMA connector]], compatible with Tektronix TDS 800 Series ([[TDS820]], [[TDS840]]) scopes. See also [[P6206]]. | The '''Tektronix P6207''' is an active 10× FET probe with a [[Tekprobe SMA connector]], compatible with Tektronix TDS 800 Series ([[TDS820]], [[TDS840]]) scopes. See also [[P6206]]. |
Latest revision as of 03:28, 21 July 2022
The Tektronix P6207 is an active 10× FET probe with a Tekprobe SMA connector, compatible with Tektronix TDS 800 Series (TDS820, TDS840) scopes. See also P6206.
Key Specifications
Bandwidth | 4 GHz |
---|---|
Input Impedance | 100 kΩ // 0.4 pF |
Output | must be terminated into 50 Ω |