R7103: Difference between revisions
Jump to navigation
Jump to search
(new in 1985 catalog) |
No edit summary |
||
Line 10: | Line 10: | ||
|designers=Val Garuts;Gene Andrews;Hans Springer;John Addis;Wink Gross;Art Metz;Aris Silzars;Conrad Odenthal;Dave Morgan; | |designers=Val Garuts;Gene Andrews;Hans Springer;John Addis;Wink Gross;Art Metz;Aris Silzars;Conrad Odenthal;Dave Morgan; | ||
|manuals= | |manuals= | ||
* [[Media:070-5039-00.pdf|R7103 Service Manual]] | * [[Media:070-5039-00.pdf|R7103 Service Manual]] | ||
}} | }} | ||
The '''Tektronix R7103''' is a 1 GHz mainframe, the rack-mount version of the [[7104]]. | The '''Tektronix R7103''' is a 1 GHz mainframe, the rack-mount version of the [[7104]]. | ||
Line 47: | Line 47: | ||
|- | |- | ||
!rowspan=2| Mainframe only | !rowspan=2| Mainframe only | ||
! Catalog | ! Catalog Price | ||
|align=right| $22,920 | |align=right| $22,920 | ||
|align=right| $30,200 | |align=right| $30,200 | ||
|- | |- | ||
! In | ! In 2023 Dollars | ||
|align=right| $ | |align=right| $65,600 | ||
|align=right| $ | |align=right| $71,100 | ||
|- | |- | ||
!rowspan=2| Mainframe with<br />[[7A29]] and [[7B10]] | !rowspan=2| Mainframe with<br />[[7A29]] and [[7B10]] | ||
! Catalog | ! Catalog Price | ||
|align=right| $28,155 | |align=right| $28,155 | ||
|align=right| $37,075 | |align=right| $37,075 | ||
|- | |- | ||
! In | ! In 2023 Dollars | ||
|align=right| $ | |align=right| $80,500 | ||
|align=right| $ | |align=right| $87,300 | ||
|- | |- | ||
|} | |} | ||
Line 96: | Line 96: | ||
''"All of the diagnostic equipment, and much of the construction equipment in the tunnel complex were lost as a result of heat damage and radiation contamination. At present, the loss of normally recoverable and reusable equipment is reported at approximately 32 million dollars."''<ref>https://www.osti.gov/servlets/purl/6607938 ''Containment and Safety Review for the Mighty Oak Nuclear Weapon Effects Test'' (1987)</ref> | ''"All of the diagnostic equipment, and much of the construction equipment in the tunnel complex were lost as a result of heat damage and radiation contamination. At present, the loss of normally recoverable and reusable equipment is reported at approximately 32 million dollars."''<ref>https://www.osti.gov/servlets/purl/6607938 ''Containment and Safety Review for the Mighty Oak Nuclear Weapon Effects Test'' (1987)</ref> | ||
</blockquote> | </blockquote> | ||
($32M in 1986 is almost $ | ($32M in 1986 is almost $90M in 2023 dollars.) | ||
<gallery> | <gallery> | ||
Line 108: | Line 108: | ||
<references /> | <references /> | ||
{{ | ==Components== | ||
{{Parts|R7103}} | |||
[[Category:7000 series non-storage mainframes]] | [[Category:7000 series non-storage mainframes]] | ||
[[Category:Micro-channel plate CRTs]] | [[Category:Micro-channel plate CRTs]] |