RG501: Difference between revisions

no edit summary
No edit summary
No edit summary
 
(9 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{TM500 | mfg=Tektronix | type=RG501| function=ramp generator | class=function generator | image=rg501.jpg | introduced=1973 | discontinued=1982 |
{{TM500 | mfg=Tektronix | type=RG501| function=ramp generator | class=function generator | image=rg501.jpg | introduced=1972 | discontinued=1982  
designers= |manuals=
|designers=Rashmi Pace
* [http://w140.com/070-1352-00_RG501_Jul72.pdf Tektronix RG501 Manual (early, PDF)]
|manuals=
* [http://w140.com/smb/RG501_SM.pdf Tektronix RG501 Manual (late, OCR, PDF)]
* [[Media:070-1352-00.pdf|Tektronix RG501 Manual 070-1352-00]] (early)
* [[Media:070-1352-01.pdf|Tektronix RG501 Manual 070-1352-01]] (late)
}}
}}
It produces a linear ramp signal adjustable up to 10 V amplitude, positive or negative, with a duration from 10 μs to 10 s (equivalent to 1 μs/Div to 1 s/Div  
It produces a linear ramp signal adjustable up to 10 V amplitude, positive or negative, with a duration from 10 μs to 10 s (equivalent to 1 μs/Div to 1 s/Div  
Line 17: Line 18:
{{Spec | Gate output | 3 V, 160 Ω source impedance }}
{{Spec | Gate output | 3 V, 160 Ω source impedance }}
{{EndSpecs}}
{{EndSpecs}}
==Links==
* [http://www.barrytech.com/tektronix/tektm500/tekrg501.html RG501 @ barrytech.com]
{{Documents|Link=RG501}}
==Rear Interface==
<small>
{| class="wikitable"
|-
! Connector Pin
! Signal
|-
| 28A      || Ramp output (common on 27A)
|-
| 25A      || Gate output (common on 26A)
|-
| 24B      || Internal trigger input (common on 25B)
|-
| 22B      || Auxiliary ground
|}
</small>


==Internals==
==Internals==
The RG501 uses Tek custom ICs [[155-0056-00]] (sweep control) and [[155-0042-03]] (Miller integrator).
The RG501 uses Tek custom ICs [[155-0056-00]] (sweep control) and [[155-0042-03]] (Miller integrator).


==Links==
==Service Notes==
* [http://www.barrytech.com/tektronix/tektm500/tekrg501.html RG501 @ barrytech.com]
If Line Trigger is OK but the power supplies load down in other trigger modes, suspect Q15 is installed incorrectly because of different case styles.
 
==Prices==
{| class="wikitable sortable"
|-
! Year
! 1975
|-
! Catalog Price
| align="right" | $175
|-
! In 2023 Dollars
| align="right" | $1,000
|}


==Pictures==
==Pictures==
Line 30: Line 65:
Tek rg501 2.jpg
Tek rg501 2.jpg
Tek rg501 3.jpg
Tek rg501 3.jpg
RG501 Top.jpg
RG501 Bottom.jpg
</gallery>
</gallery>


{{Custom ICs|RG501}}
==Components==
{{Parts|RG501}}