36,230
edits
No edit summary |
m (Text replacement - "Category: Spectrum Analyzers" to "Category:Spectrum analyzers") |
||
(5 intermediate revisions by one other user not shown) | |||
Line 7: | Line 7: | ||
discontinued=(?) | | discontinued=(?) | | ||
manuals= | manuals= | ||
* [[Media: 37W-26274-19_RSA5000-Series-Spectrum-Analyzers-Datasheet.pdf | 37W-26274-19 RSA5000 Series Spectrum Analyzers Datasheet (PDF, OCR)]] | * [[Media: 37W-26274-19_RSA5000-Series-Spectrum-Analyzers-Datasheet.pdf | 37W-26274-19 RSA5000 Series Spectrum Analyzers Datasheet (PDF, OCR)]] | ||
* [[Media: 071-3224-11_RSA5100B-Real-Time-Spectrum-Analyzer-Quick-Start-User-Manual-EN.pdf | 071-3224-11 RSA5100B Real-Time Spectrum Analyzer Quick Start User Manual (PDF, OCR)]] | * [[Media: 071-3224-11_RSA5100B-Real-Time-Spectrum-Analyzer-Quick-Start-User-Manual-EN.pdf | 071-3224-11 RSA5100B Real-Time Spectrum Analyzer Quick Start User Manual (PDF, OCR)]] | ||
* [[Media: 071-3283-00_RSA5100B-Real-Time-Spectrum-Analyzers-Application-Examples-Reference-EN.pdf | 071-3283-00 RSA5100B Real Time Spectrum Analyzers Application Examples Reference (PDF, OCR)]] | * [[Media: 071-3283-00_RSA5100B-Real-Time-Spectrum-Analyzers-Application-Examples-Reference-EN.pdf | 071-3283-00 RSA5100B Real Time Spectrum Analyzers Application Examples Reference (PDF, OCR)]] | ||
* [[Media: 077- | * [[Media: 077-0901-04_RSA5100B-Real-Time-Spectrum-Analyzer-Programmer-Manual-EN.pdf | 077-0901-04 RSA5100B-Real-Time-Spectrum-Analyzer-Programmer-Manual (PDF, OCR)]] | ||
* [[Media: 077-0903-00_RSA5100B-Service-Manual-Rev-A.pdf | 077-0903-00 RSA5100B Service –Manual (PDF, OCR)]] | |||
}} | }} | ||
Line 26: | Line 26: | ||
Front panel inputs/outputs are: RF INPUT [[N connector]] (50Ω, +30 dBm w/pre-amp off, +20 dBm w/pre-amp on); Trig IN [[BNC connector]] (External trigger input; -2.5 V to +2.5 V range); Trig OUT [[BNC connector]] (Trigger output; 50Ω, high > 2.0 V, low < 0.4 V, 1 mA); and 2 X [[USB connector]]s (USB 2.0). | Front panel inputs/outputs are: RF INPUT [[N connector]] (50Ω, +30 dBm w/pre-amp off, +20 dBm w/pre-amp on); Trig IN [[BNC connector]] (External trigger input; -2.5 V to +2.5 V range); Trig OUT [[BNC connector]] (Trigger output; 50Ω, high > 2.0 V, low < 0.4 V, 1 mA); and 2 X [[USB connector]]s (USB 2.0). | ||
Rear panel inputs/outputs: | Rear panel inputs/outputs: [[GPIB connector]] (IEEE 488.2); Analog Zero Span Out [[BNC connector]] (Opt. 66); Real Time I and Q out [[MDR Connector]]s (Opt. 65); Noise Source Drive [[BNC connector]] (+28 V DC Out, 140 mA (nominal), turn ON time: 100 µs, turn OFF time: 500 µs); LINE OUT [[Phone connector]] (Headphone audio out); MIC [[Phone connector]] (Microphone in); NOT IN USE [[Phone connector]] (Line In not supported); Trig 2 In [[BNC connector]] (External trigger TTL 7V Max); COM 2 [[DB9 connector]] (Male pins, serial port for connecting peripherals); [[VGA Connector]] (External monitor, resolution not limited to VGA); Keyboard [[Mini DIN connector]] (PS2 Keyboard); 2 X USB 2.0 [[USB connector]]s (For mouse and other peripherals); LAN [[Ethernet]] connector (RJ45 10/100/1000 Base T network); REF OUT [[BNC connector]] (Reference frequency, 10 MHz, >0 dBm, 5V Max); REF IN [[BNC connector]] (Reference frequency, 10 MHz, -10 dBm to +5 dBm, 5V Max); and US Power Plug (115 V nominal) . | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 111: | Line 111: | ||
* RSA5BUP WIN10REM: A removable solid-state drive. The Windows 10 operating system and instrument software is preinstalled. | * RSA5BUP WIN10REM: A removable solid-state drive. The Windows 10 operating system and instrument software is preinstalled. | ||
* RSA5BUP WIN10INT: An internally mounted drive. The Windows 10 operating system and instrument software is preinstalled. | * RSA5BUP WIN10INT: An internally mounted drive. The Windows 10 operating system and instrument software is preinstalled. | ||
==Service Options== | |||
* Opt. CA1: Single Calibration or Functional Verification | |||
* Opt. C3: Calibration Service 3 Years | |||
* Opt. C5: Calibration Service 5 Years | |||
* Opt. D1: Calibration Data Report | |||
* Opt. D3: Calibration Data Report 3 Years (with Opt. C3) | |||
* Opt. D5: Calibration Data Report 5 Years (with Opt. C5) | |||
* Opt. G3: Complete Care 3 Years (includes loaner, scheduled calibration, and more) | |||
* Opt. G5: Complete Care 5 Years (includes loaner, scheduled calibration, and more) | |||
* Opt. R5: Repair Service 5 Years (including warranty) | |||
==Pictures== | ==Pictures== | ||
Line 119: | Line 130: | ||
</gallery> | </gallery> | ||
[[Category: Spectrum | [[Category:Spectrum analyzers]] |