The S-3 sampling head is a plug-in head for use with the | {{Plugin Sidebar | ||
7000 series sampling plug-ins or | |manufacturer=Tektronix | ||
|series=7000 and 3S series sampling heads | |||
|type=S-3 | |||
|summary=Sampling Head | |||
|image=S3a box front.jpg | |||
|caption=S-3A head | |||
|introduced=1969 | |||
|discontinued=1989 | |||
|manuals= | |||
* [[Media:070-0765-00.pdf|Tektronix S-3 Manual]] (PDF) / [http://bama.edebris.com/download/tek/s3/s3.djvu @ BAMA] (DjVu) | |||
* [[Media:070-1148-01.pdf|Tektronix S-3A Manual]] (PDF) | |||
}} | |||
The '''Tektronix S-3 sampling head''' is a plug-in head for use with the 7000 series sampling plug-ins or the Type [[3S2]], [[3S5]], and [[3S6]] samplers. | |||
The | The plug-in includes a permanently attached 1× probe with the sampling bridge enclosed in the probe. | ||
Optional 10× or 100× attenuator tips (010-0364-00, 010-0365-00) provide extended input voltage range; the optional [[VP-2]] voltage pickoff converts it to a 50 Ω feed-through sampling head. | |||
{{BeginSpecs}} | |||
{{Spec | Rise time | ≤350 ps (×10, ≤400 ps; ×100, ≤500 ps) }} | |||
{{Spec | Input impedance | 100 kΩ // 2.3 pF (×10, 1 MΩ // 2 pF; ×100, 1 MΩ // 1.7 pF) }} | |||
{{Spec | Maximum signal | 2 V<sub>p-p</sub> (×10, 20 V<sub>p-p</sub>; ×100, 200 V<sub>p-p</sub>) }} | |||
{{Spec | Maximum safe input | max. ±100 V, max. sine input 20 V<sub>p-p</sub> (×10 or ×100, max. ±350 V, max. sine input 200 V<sub>p-p</sub>) }} | |||
{{Spec | Features | | |||
* no trigger pickoff for internal triggering | |||
* offset voltage of either ±1 V or ±2 V (at ×1) can be selected via a toggle switch on the front panel | |||
}} | |||
{{EndSpecs}} | |||
== Differences between S-3 and S-3A == | ==Differences between S-3 and S-3A == | ||
The S-3A sampling head has | The S-3A sampling head has a 10× improvement in baseline shift due to cable flexing. | ||
All other specifications are identical to the ordinary S-3. | |||
== Difference between the S-3 and the P6038 == | The major differences in design involves the gate board in the box part of the probe, | ||
The S-3 probe contains a compensated attenuator before the sampling bridge. | but some changes are also made to the circuits in the body of the probe. | ||
The S-3 probe has a JFET buffer between the holding cap and the probe cable. | |||
Both use the [[152-0368-00]] sampling bridge. | ==Difference between the S-3 and the P6038 == | ||
The S-3 probe contains a compensated attenuator before the sampling bridge. | |||
The [[P6038]] does not. | |||
The S-3 probe has a JFET buffer between the holding cap and the probe cable. | |||
The P6038 does not. | |||
Both use the [[152-0368-00]] sampling bridge. The sampling pulse is generated by a [[snap-off diode]] ([[152-0368-00]]). | |||
== Repair of Sampling Diodes == | == Repair of Sampling Diodes == | ||
Individuals have reported success in replacing the S-3 sampling diodes with Agilent matched pair Schottky diodes. | Individuals have reported success in replacing the S-3 [[Sampling_diodes|sampling diodes]] with Agilent matched pair Schottky diodes. | ||
==Pictures== | |||
'''S-3''' | |||
<gallery> | |||
Tek s3 probe sample bridge.jpg|S-3 probe sampling bridge | |||
Tek s3 sample bridge2.jpg|S-3 probe sampling bridge | |||
S3_frontend.png | S-3 frontend circuit | |||
</gallery> | |||
'''S-3A''' | |||
<gallery> | <gallery> | ||
S3a attenuator.jpg|010-0364-00 ×10 attenuator for S-3A | |||
S3a box front.jpg|Front | |||
S3a probe external1.jpg|S-3A probe | |||
S3a probe internal1.jpg|S-3A probe internal | |||
S3a probe internal2.jpg|S-3A probe internal | |||
S3a strobe board.jpg|S-3A strobe board | |||
S3a probe_internal_bothsides.jpg|S-3A probe both sides | |||
</gallery> | </gallery> | ||
[[Category:7000 and 3S series sampling heads]] | [[Category:7000 and 3S series sampling heads]] |