{{Plugin Sidebar |
title=Tektronix S-3 |
summary=Sampling Head |
image=S3a box front.jpg |
caption=S-3A head |
series=[[:Category:Sampling plugins|7000/S3 series Sampling Plugins]] |
years=? – ? |
manuals=
* [http://bama.edebris.com/download/tek/s3/s3.djvu Tektronix S-3 Manual (DjVu)]
* [http://w140.com/tek_s-3.pdf Tektronix S-3 Manual (PDF)]
}}
The S-3 sampling head is a plug-in head for use with the  
The S-3 sampling head is a plug-in head for use with the  
7000 series sampling plug-ins or with the Type [[3S2]], [[3S5]], or [[3S6]] samplers.  
7000 series sampling plug-ins or with the Type [[3S2]], [[3S5]], or [[3S6]] samplers.  
The plug-in includes a permanently attached 1x probe with the sampling bridge enclosed in the probe.
The plug-in includes a permanently attached probe with the sampling bridge enclosed in the probe.  Optional 10× or 100× attenuator tips are available.


The input rise time is specified as less than 350 ps for the 1× probe, less than 400 ps with the optional 10× attenuator tip, and less than 500 ps with the 100× attenuator tip.
==Specifications==
The maximum operating signal voltage is 2 V<sub>p-p</sub>.
The S-3 does not provide a trigger pickoff for internal triggering.
An offset voltage of either +/- 1 V or +/- 2 V can be selected via a toggle switch on the front panel.


== Input Characteristics ==
* Input rise time:
The probe tip input is equivalent to 100 kΩ resistor in parallel with about 2.3 pF capacitance at low frequency.
** 1×: < 350 ps
With the 10× or 100× attenuator tips, the probe input is equivalent to 1 MΩ paralleled with 2 pF or 1.7 pF, respectively.
** 10×: < 400 ps
** 100×: < 500 ps
* Input impedance:
** 1×: 100 kΩ || 2.3 pF at low frequency
** 10×: 1 MΩ || 2 pF
** 100×: 1 MΩ || 1.7 pF
* Maximum signal voltage: 2 V<sub>p-p</sub>
* The S-3 does not provide a trigger pickoff for internal triggering.
* An offset voltage of either +/- 1 V or +/- 2 V can be selected via a toggle switch on the front panel.


== Differences between S-3 and S-3A ==
== Differences between S-3 and S-3A ==
Line 22: Line 38:
== Repair of Sampling Diodes ==
== Repair of Sampling Diodes ==
Individuals have reported success in replacing the S-3 sampling diodes with Agilent matched pair Schottky diodes.
Individuals have reported success in replacing the S-3 sampling diodes with Agilent matched pair Schottky diodes.
* [http://bama.edebris.com/download/tek/s3/s3.djvu Tektronix S-3 Manual (DjVu)]
* [http://w140.com/tek_s-3.pdf Tektronix S-3 Manual (PDF)]


==Pictures==
==Pictures==
<gallery>
<gallery>
Image:S3_frontend.png
Image:S3_frontend.png
File:S3a attenuator.jpg|S-3A|S-3A attenuator
File:S3a attenuator.jpg|S-3A attenuator
File:S3a box front.jpg
File:S3a box front.jpg|Front
File:S3a probe external1.jpg|S-3A probe
File:S3a probe external1.jpg|S-3A probe
File:S3a probe internal1.jpg|S-3A probe internal
File:S3a probe internal1.jpg|S-3A probe internal
Line 41: Line 54:


[[Category:7000 and 3S series sampling heads]]
[[Category:7000 and 3S series sampling heads]]
__NOTOC__