36,479
edits
No edit summary |
No edit summary |
||
(14 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
The T5430 is a CRT used in the [[545|545A]]. | [[File:T543-P2-1.jpg|thumb|350px|right]] | ||
The '''T5430''' aka '''T543''' aka '''T65''' is a 5" CRT used in the [[541|541A]], [[543]] and [[543|543A]] (but not 543B), and [[545|545A]] scopes. | |||
When furnished with P2 phosphor, the T5430 is designated the T5430-2 | |||
and has has part number 154-175. | The tube has [[helical post-acceleration]] at typically about 10 kV. | ||
Horizontal deflection sensitivity is 29.5 Volts/cm, sweep length is 10 cm. | |||
Vertical deflection is limited to 4 cm at 6.75 Volts/cm sensitivity. | |||
Deflection plates are non-distributed, system bandwidth is about 30 MHz. | |||
When furnished with P2 phosphor, the T5430 is designated the T5430-2 and has has part number 154-175. | |||
==Part Numbers== | |||
{| class="wikitable" | |||
|- | |||
! Part No | |||
! Name | |||
! Phosphor | |||
|- | |||
| 154-0175-00 (154-175) || T65 P2 / T543 P2 (T5430-2) || P2 (Standard) | |||
|- | |||
|} | |||
==Data== | |||
* [[Media:T543P_crt_data.pdf|Tektronix T543 Datasheet (PDF)]] | |||
* [[Media:Tek 5ELP T5430 datasheet.pdf|Tektronix 5ELP/T5430 Datasheet (PDF)]] | |||
* [[Media:T5430_perf_data.pdf|Tektronix T543P Performance Data (PDF)]] | |||
==Pictures== | |||
<gallery> | |||
154-0175-00 1.jpg | |||
154-0175-00 2.jpg | |||
T543-P2-1.jpg | |||
T543-P2-2.jpg | |||
T543-P2-3.jpg | |||
T543-P2-4.jpg | |||
T543-P2-5.jpg | |||
T543-P2-6.jpg | |||
</gallery> | |||
[[Category:Cathode ray tubes]] |