TDS544A: Difference between revisions

From TekWiki
Jump to navigation Jump to search
mNo edit summary
(Added part number for Field Adjustment Software v1.6)
(4 intermediate revisions by the same user not shown)
Line 51: Line 51:


==Software==
==Software==
* [[Media:Tek_TDS500_Field_Adjustment_Software.zip|TDS500 Field Adjustment Software]] (ZIP)
* [[Media:TDS500-500A_V1.4_Field_Adjustment_Software.zip|TDS544A V1.4 Field Adjustment Software]] (ZIP)
* [[Media:TDS500-500A_V1.4_Field_Adjustment_Software.zip|TDS544A V1.4 Field Adjustment Software]] (ZIP)
* [[Media:TDS500-500A_V1.6_Field_Adjustment_Software.zip|TDS544A V1.6 Field Adjustment Software]] (ZIP)
* [[Media:TDS500-500A_V1.6_Field_Adjustment_Software.zip|TDS544A V1.6 Field Adjustment Software 063-1642-00]] (ZIP)
* [[Media:TDS500-500A_V1.11_Field_Adjustment_Software.zip|TDS544A V1.11 Field Adjustment Software]] (ZIP)
* [[Media:TDS500-500A_V1.11_Field_Adjustment_Software.zip|TDS544A V1.11 Field Adjustment Software]] (ZIP)
<br>
<br>
* [[Media:Tek_TDS500_Field_Adjustment_Software.zip|TDS500 Field Adjustment Software]] (ZIP)
* [[Media:063-1134-00 V1.2.zip|TDS Family Programming Examples Software 063-1134-00 V1.2]] (ZIP)
* [[Media:TDS300-400-500-600-700-800_AWE_Drivers_066008700.zip|Tektronix TDS300, 400, 500, 600, 700, 800 AWE Drivers 066-0087-00]] (ZIP)
* [[Media:066-0002-00.zip|Waveform Converter For Oscilloscopes 066-0002-00]] (ZIP)
* [[Media:066-0087-00.zip|AWE Drivers For Tektronix Oscilloscopes 066-0087-00]] (ZIP)
* [[Media:066-0104-00.zip|File Transfer Utility From TDS Scope To PC 066-0104-00]] (ZIP)
* [[Media:066-0125-00.zip|Enhanced Printing Utility for TDS Family]] (ZIP)
* [[Media:066-0125-00.zip|Enhanced Printing Utility for TDS Family]] (ZIP)
* [[Media:066-0165-00.zip|Tektronix TDS500C/700C Custom Masks 066-0165-00]] (ZIP)
* [[Media:066-0176-00.zip|WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00]] (ZIP)
* [[Media:066-0177-00.zip|Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00]] (ZIP)
* [[Media:066-0178-00.zip|Example Program To Get Crossing Levels 066-0178-00]] (ZIP)
* [[Media:066-0179-00.zip|TDS ISF File To CSV File Conversion Utility 066-0179-00]] (ZIP)
* [[Media:066-0183-00.zip|TDS Sandisk Hard Disk Patch Utility 066-0183-00]] (ZIP)
* [[Media:066-0188-00.zip|Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00]] (ZIP)
* [[Media:066-0194-00.zip|TDS Waveform Logging Sample Program 066-0194-00]] (ZIP)
* [[Media:066-0196-00.zip|Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00]] (ZIP)
* [[Media:066-0197-00.zip|Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00]] (ZIP)
* [[Media:066-0198-00.zip|Transfer Setups Between TDS Oscilloscopes 066-0198-00]] (ZIP)
* [[Media:066-0200-00.zip|VB Program To Capture TDS Extended Waveforms 066-0200-00]] (ZIP)
* [[Media:066-0489-00.zip|TDS Series WFM File Formatter 066-0489-00]] (ZIP)
* [[Media:Wavestar_2012.05.09.11.07.29_16456_EN.zip|Tektronix Wavestar 2012.05.09.11.07.29 16456 EN 066-0934-03]] (ZIP, 102MB) ''Product Key: WSTRO618650124''


==Firmware==
==Firmware==

Revision as of 08:27, 27 November 2022

Manuals – Specifications – Links – Pictures


The Tektronix TDS544A is a 500 MHz, 1 GS/s quad-channel digital scope with a color screen.

Specifications

  • 500 MHz bandwidth
  • color CRT
  • sample rates to 1 GSa/s
  • 25 automatic measurements
  • 4 input channels
  • 3.5" floppy drive
  • sensitivity of 1 mV to 10 V per division
  • time base range of 500 ps to 10 s/div
  • waveform Pass/Fail testing
  • record lengths of up to 50,000 points

Software


Firmware

Options

  • 05 - Video Trigger
  • 13 - RS-232/Centronics Hardcopy Interface. Standard on TDS524A-TDS544A.
  • 1F - FILE SYSTEM, standard on TDS524A-TDS544A.
  • 1K - K420 Oscilloscope Cart without power strip
  • 1M - 50k Memory Length
  • 1R - Rackmount
  • 23 - Add two each P6205 Active Probes
  • 25 - Add P6563A, four SMD probes
  • 2F - Advanced DSP Math

Links