P6135
(Redirected from P6135A)
The Tektronix P6135(A) is a differential probe pair matched to minimize differences in impedance and signal delay, to maintain CMRR up to 20,000:1 when used with differential amplifiers such as the 7A13, 7A22 or 11A33. Note that unlike most x10 probes, the P6135 and P6135A have an input resistance of 1 MΩ rather than 10 MΩ.
The P6135 is a subminiature modular probe with a limited compensation range around 15 pF. The P6135A is a larger compact modular probe and comes with three different tips for increased compensation range, matching the 11A33 − red, 7A13 − black, and 7A22 − blue. The P6135A model can therefore be seen as a replacement of the P6055.
Key Specifications
Bandwidth | 150 MHz on 11A33, 90 MHz on 7A13 |
---|---|
Max. Input | ±500 V (DC + peak AC) derated above 1.3 MHz |
Attenuation | Adjustable to ×10 |
Compensation Range |
|
Input Impedance |
|
CMRR | 10,000:1 on 11A33, 20,000:1 on 7A13 |