The '''Tektronix Type 1A1''' plug-in for the [[500-series scopes]] has two channels and a -3 dB point of 50 MHz at 50 mV/Div, 28 MHz at 5 mV/Div, and 2 Hz to 15 MHz at 500 μV/Div when channels 1 and 2 are cascaded.
The '''Tektronix Type 1A1''' plug-in for the [[500-series scopes]] has two channels and a -3 dB point of 50 MHz at 50 mV/Div, 28 MHz at 5 mV/Div, and 2 Hz to 15 MHz at 500 μV/Div when channels 1 and 2 are cascaded.


Early production used a [[Nuvistor]] front-end,  
There were three distinct versions of 1A1.
and [[rotary_input_switch|rotary input switches]] that were concentric
* The first version, from 1964 to 1966, has a [[Nuvistor]] front-end, and [[rotary_input_switch|rotary input switches]] that were concentric with the [[BNC]] jacks. The knobs to invert the input channels are concentric with the the vertical position knobs.
with the [[BNC]] jacks, while later units have FETs and lever switches.
* The second version, from 1966 to ??? has fluted round V/cm knobs, and lever switches. The channel inversion control is an organ-style pull-push knob.
* The third model, from ??? until the end has four-sided V/cm knobs and a FET front-end.
 
Type 1A1 uses the "ALT SWEEP SLAVE PULSE" signal that is sent by scopes on pin 7 of the plug-in connector.   
Type 1A1 uses the "ALT SWEEP SLAVE PULSE" signal that is sent by scopes on pin 7 of the plug-in connector.   
In a Type [[547]] mainframe,  
In a Type [[547]] mainframe,  