33,087
edits
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
The Tektronix 107 is a squarewave generator. It was intended to be used for calibration | The Tektronix 107 is a squarewave generator. It was intended to be used for calibration | ||
of oscilloscopes. It is designed to provide a clean waveform with fast edges and flat | of oscilloscopes. It is designed to provide a clean waveform with fast edges and flat | ||
tops. The signal starts with an astable | tops. The signal path starts with an astable | ||
multivibrator composed of both halves of a 6BQ7A dual triode tube. The multivibrator | multivibrator composed of both halves of a 6BQ7A dual triode tube. The multivibrator | ||
circuit is cathode coupled to a pulse shaping circuit, and then to an output stage | circuit is cathode coupled to a pulse shaping circuit, and then to an output stage |