494: Difference between revisions

Jump to navigation Jump to search
2 bytes added ,  7 July 2019
no edit summary
No edit summary
No edit summary
Line 28: Line 28:
NOTE: Both HORIZ and VERT output signals are driven from digital storage if it is on.  Both signals are driven from the analyzer sweep and video amplifier stage if digital storage is off;
NOTE: Both HORIZ and VERT output signals are driven from digital storage if it is on.  Both signals are driven from the analyzer sweep and video amplifier stage if digital storage is off;


PEN LIFT (OUTPUT) [[BNC connector]] (Provides access to a TTL compatible signal to lift the pen of a chart recorder during sweep retrace.  This signal is always derived from the spectrum analyzer sweep.  In Opt. 42 instruments, use this connector to input external video signals if pin 1 of the ACCESSORIES connector is grounded; 10 MHz IF (OUTPUT) [[BNC connector]] (Provides access to the output of the 10 MHz IF); EXT REF IN [[BNC connector]] (A 50Ω input for a 1, 2, 5, or 10 MHz external reference signals, within -15 dBm to +15 dBm level.  Input signals must be a sinewave with a duty cycle symmetry of 40% to 60%, or ECL or TTL); J104 ACCESSORY (B053575 AND UP) female [[DB25 connector]] (Provides bidirectional access to the instrument bus.  For instruments B053574 and below, this connector has no application.); IEEE STD 488 PORT [[GPIB interface]] (Added to all "P" suffixed instruments)
PEN LIFT (OUTPUT) [[BNC connector]] (Provides access to a TTL compatible signal to lift the pen of a chart recorder during sweep retrace.  This signal is always derived from the spectrum analyzer sweep.  In Opt. 42 instruments, use this connector to input external video signals if pin 1 of the ACCESSORIES connector is grounded; 10 MHz IF (OUTPUT) [[BNC connector]] (Provides access to the output of the 10 MHz IF); EXT REF IN [[BNC connector]] (A 50Ω input for a 1, 2, 5, or 10 MHz external reference signals, within -15 dBm to +15 dBm level.  Input signals must be a sinewave with a duty cycle symmetry of 40% to 60%, or ECL or TTL); J104 ACCESSORY (B053575 AND UP) female [[DB25 connector]] (Provides bidirectional access to the instrument bus.  For instruments B053574 and below, this connector has no application.); IEEE STD 488 PORT [[GPIB interface]] (Added to all "P" suffixed instruments)




Line 53: Line 53:
{{Spec | Power | 90 − 132 V<sub>AC</sub>, 48 to 440 Hz; 180 – 250 V<sub>AC</sub>, 48 to 440 Hz.  At 115 V<sub>AC</sub>, 60 Hz, 210 W max }}
{{Spec | Power | 90 − 132 V<sub>AC</sub>, 48 to 440 Hz; 180 – 250 V<sub>AC</sub>, 48 to 440 Hz.  At 115 V<sub>AC</sub>, 60 Hz, 210 W max }}
{{Spec | Operating Atmospherics | Temperatures: -15 °C to +55 °C;  Humidity: Five cycles (120 hours) MIL-STD-810; Altitude: Up to 4.6 km (15,000 ft) }}
{{Spec | Operating Atmospherics | Temperatures: -15 °C to +55 °C;  Humidity: Five cycles (120 hours) MIL-STD-810; Altitude: Up to 4.6 km (15,000 ft) }}
{{Spec | GPIB Characteristics | In accordance with IEEE Standard 488-1978 implemented as SH1, AH1, T5, L3, SR1, RL1, PP1, DC1, DT1, and C0
{{Spec | GPIB Characteristics | In accordance with IEEE Standard 488-1978 implemented as SH1, AH1, T5, L3, SR1, RL1, PP1, DC1, DT1, and C0 }}