S-2: Difference between revisions

Jump to navigation Jump to search
27 bytes added ,  25 March 2020
m
no edit summary
No edit summary
mNo edit summary
Line 33: Line 33:


*The input should always be terminated when not in use because the [[sampling diodes]] are easily damaged by excessive inputs or static discharge.  See that article for possible replacements.
*The input should always be terminated when not in use because the [[sampling diodes]] are easily damaged by excessive inputs or static discharge.  See that article for possible replacements.
*The ground contact of R4 can become intermittent, causing the input impedance to go high or fluctuating. The cure is to disassemble the sampler incuding the sampler board covers, and then carefully bend the ground tabs of the input termination resistor outward.
*The ground contact of input termination resistor R4 can become intermittent, causing the input impedance to go high or fluctuating. The cure is to disassemble the sampler incuding the sampler board covers, and then carefully bend the ground tabs of the input termination resistor outward.


==Pictures==
==Pictures==
1,991

edits

Navigation menu