Talk:11000 Series plug-in interface: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
No edit summary
Line 19: Line 19:
Is it just me, or is that confusing since those compartments are for vertical-axis signals?
Is it just me, or is that confusing since those compartments are for vertical-axis signals?
[[User:Kurt|Kurt]] ([[User talk:Kurt|talk]]) 14:52, 11 March 2021 (PST)
[[User:Kurt|Kurt]] ([[User talk:Kurt|talk]]) 14:52, 11 March 2021 (PST)
----
Kurt, I also cannot claim any expertise in the 11000 series scopes, but based on [[Media:The 11400 story.pdf|Story of 11400 Development]] (who is the author?) and the mentioned [[Media:Tek 11000-series plug-in to main frame interface manual.pdf|11000-Series Plug-in to Main Frame Interface Manual]] I totally agree with you. The interface manual also lists compatibility of 7k plugins, but does not mention the mechanical obstruction from plugging them in without modification. Also the modified [[067-0587-10]] is listed in some 11k mainframe manuals in the calibration section. So my personal conclusion is that 7k plugins should be working in most (?) 11k mainframes with the limitations listed in [[Media:Tek 11000-series plug-in to main frame interface manual.pdf|11000-Series Plug-in to Main Frame Interface Manual]].
However, [[John Addis]] says they dont: [[Similarity_of_11000-series_interface_and_7000-series_interface]]. (However he seems to mostly talk about how 11k plugins dont work in 7k mainframes) Based on that I was initially tempted to remove the statement in the [[11401]] page that 7k plugins are compatible. Conclusion: Its quite confusing to me at this point.
[[User:Gregor|Gregor]] ([[User talk:Gregor|talk]]) 19:30, 11 March 2021 (MST)
1,992

edits

Navigation menu