1,330
edits
Jaredcabot (talk | contribs) (Added photos) |
Jaredcabot (talk | contribs) mNo edit summary |
||
Line 15: | Line 15: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
The TM504 supplies five unregulated voltages to the plug-in modules: | The TM504 supplies five unregulated voltages to the plug-in modules:<br> | ||
Low Power Compartment: | Low Power Compartment: | ||
* +33.5 V, 1.4 A max shared by all compartments. | * +33.5 V, 1.4 A max shared by all compartments. | ||
* −33.5 V, 1.4 A max shared by all compartments. | * −33.5 V, 1.4 A max shared by all compartments. | ||
* 2 × 25 V<sub>AC</sub>, 0.5 A / 25 VA | * 2 × 25 V<sub>AC</sub>, 0.5 A / 25 VA; floating ≤350 V (peak) per low power compartment. | ||
* +11.5 V, and 17.5 V<sub>AC</sub> with grounded centre tap, 3.6 A max shared between all three low power compartments. | * +11.5 V, and 17.5 V<sub>AC</sub> with grounded centre tap, 3.6 A max shared between all three low power compartments. | ||
edits