1,344
edits
Jaredcabot (talk | contribs) m (Typo in Simmconn Labs URL) |
Jaredcabot (talk | contribs) (Added Manuals and Options, formatting etc.) |
||
Line 9: | Line 9: | ||
|discontinued=(?) | |discontinued=(?) | ||
|designers= | |designers= | ||
| | |Manuals=See Below | ||
}} | }} | ||
The '''Tektronix TDS784''' is a 1 GHz, 4 GS/s quad-channel digital storage scope. | The '''Tektronix TDS784''' is a 1 GHz, 4 GS/s quad-channel digital storage scope. | ||
Line 33: | Line 29: | ||
* I/O: Full GPIB programmability | * I/O: Full GPIB programmability | ||
* Hardcopy output using [[GPIB]], [[RS-232]], or Centronics ports | * Hardcopy output using [[GPIB]], [[RS-232]], or Centronics ports | ||
==Manuals== | |||
* [https://w140.com/tekwiki/images/c/cd/070-8709-07.pdf TDS 410A, 420A, 460A, 520A, 524A, 540A, 544A, 620A, 640A, 644A, 684A, 744A & 784A Programmer Manual 070-8709-07 (PDF)] | |||
* [https://w140.com/tekwiki/wiki/File:070-8990-04.pdf TDS684A, 744A, 784A Performance Verification and Specifications 070-8990-04 (PDF)] | |||
* [https://w140.com/tekwiki/images/4/40/TDS684A-744A-784A_User_Manual_070-8991-02.pdf Tektronix TDS684A, 744A, 784A User Manual 070-8991-02 (PDF)] | |||
* [http://w140.com/tek_tds_684a_744a_784a_service.pdf Tektronix TDS 684A, 744A, and 784A Service Manual 070-8992-03 (PDF)] | |||
* [https://w140.com/tekwiki/images/9/90/TDS684A-744A-784A_Reference_070-8999-02.pdf TDS684A, 744A, 784A Reference 070-8999-02 (PDF)] | |||
* [http://w140.com/tek_tech_ref_TDS_520B_540B_620B_644B_680B_684B_724A_744A_784A.pdf TDS 520B, 540B, 620B, 644B, 680B, 684B, 724A, 744A, and 784A Digitizing Oscilloscopes Performance Verification and Specifications 070-9384-01 (PDF)] | |||
* [https://w140.com/tekwiki/images/4/41/070-9386-03.pdf Tektronix TDS520B, 540B, 620B, 644B, 680B, 684B, 724A, 744A, 784A Service Manual 070-9386-03 (PDF)] | |||
* [http://w140.com/manual_TDS754A.pdf TDS 500B, 600B, and 700A Digitizing Oscilloscopes 070-9719-00 (PDF)] | |||
* [https://w140.com/tekwiki/images/3/37/TDS500C-600B-700C_Reference_070-9861-00.pdf Tektronix TDS500C, 600B, 700C Reference 070-9861-00 (PDF)] | |||
* [https://w140.com/tekwiki/images/7/77/TDS500C-600B-700C_User_Manual_070-9869-00.pdf Tektronix TDS500C, 600B, 700C User Manual 070-9869-00 (PDF)] | |||
* [https://w140.com/tekwiki/wiki/File:070-9874-02.pdf TDS500C-600B-700C Technical Reference 070-9874-02 (PDF)] | |||
* [https://w140.com/tekwiki/images/a/a3/070-9875-04.pdf Tektronix TDS500C, 600B, 700C Service Manual 070-9875-04 (PDF)] | |||
* [https://w140.com/tekwiki/images/d/d9/TDS500C-600B-700C_User_Manual_Supplement_071-0090-01.pdf Tektronix TDS500C, 600B, 700C User Manual Supplement 071-0090-01 (PDF)] | |||
* [https://w140.com/tekwiki/images/4/43/071-0273-02.pdf Tektronix TDS500D, 600C, 700D User Manual Supplement 071-0273-02 (PDF)] | |||
* [https://w140.com/tekwiki/images/6/6d/071-0273-03.pdf Tektronix TDS500D, 600C, 700D User Manual Supplement EN/FR/DE/KR/JP 071-0273-03 (PDF)] | |||
* [https://w140.com/tekwiki/images/a/a6/TDS500CD-600C-700CDL_HDD_Upgrade_Manual_071-0442-02.pdf Tektronix TDS500C/D, 600C, 700C/D/L HDD Upgrade Manual 071-0442-02 (PDF)] | |||
* [https://w140.com/tekwiki/images/c/c4/071-0504-00.pdf Tektronix TDS500D, 600C, 700D Reference 071-0504-00 (PDF)] | |||
* [https://w140.com/tekwiki/images/7/7c/TDS500D-600C-700D-714L_Service_Manual_071-0627-02.pdf Tektronix TDS500D, 600C, 700D, 714L Service Manual 071-0627-02 (PDF)] | |||
* [https://w140.com/tekwiki/images/5/57/071-0630-03.pdf Tektronix TDS500D, 600C, 700D, 714L Performance Verification and Specifications 071-0630-03 (PDF)] | |||
* [https://w140.com/tekwiki/images/9/90/TDS700D_Datasheet_55W_11336_4.pdf Tektronix TDS700D Datasheet 55W_11336_4 (PDF)] | |||
==Software== | |||
* [https://w140.com/tekwiki/images/2/2e/TDS300-400-500-600-700-800_AWE_Drivers_066008700.zip Tektronix TDS300, 400, 500, 600, 700, 800 AWE Drivers 066008700 (ZIP)] | |||
* [https://w140.com/tekwiki/images/9/9a/TDS520C-540C-580C-724C-754C-784C_Custom_Masks.zip Tektronix TDS520C, 540C, 580C, 724C, 754C, 784C Custom Masks (ZIP)] | |||
* [https://w140.com/tekwiki/images/7/78/Wavestar_2012.05.09.11.07.29_16456_EN.zip Tektronix Wavestar 2012.05.09.11.07.29 16456 EN (ZIP) (102Mb)] | |||
==Options== | ==Options== | ||
* | * 05 - Video Trigger - Oscilloscope comes with tools that allow investigation of a range of NTSC, PAL, SECAM, and high definition TV signals. | ||
* 1M - 4M acquisition length - Extends standard acquisition length from 50,000 points per channel to 130,000 samples on three or four channels, 250,000 samples on two channels, and 500,000 samples on one channel. | |||
* 1M | * 13 - RS-232C and Centronics hardcopy interfaces - Add RS-232-C and Centronics interface ports. | ||
* 2F | * 1F - Floppy disk drive - Add 3.5 inch, 1.44 MByte floppy disc drive. | ||
* 2C | * 2F - Advanced DSP math - Add advanced DSP math features such as FFT, integration, and differentiation. | ||
* 2C - Communication Signal Analyzer - Oscilloscope comes configured for communications signal triggering and mask testing. | |||
* 3C - P6701B with system calibration - Oscilloscope comes with a P6701B and calibrated short-wavelength optical reference receiver on channel 1. | |||
* 4C - P6703B with system calibration - Oscilloscope comes with a P6703B and calibrated long-wavelength optical reference receiver on channel 1. | |||
* 2M - 8M acquisition length - TDS 520D, 724D: To 2M samples on two channels and 4M on one channel. TDS 540D, 580D, 714L, 754D, 784D, 794D: To 2M samples on three or four channels, 4M on two channels, and 8M samples on one channel (Option includes a hard disk and is only available for the models listed above.) | |||
==Links== | ==Links== | ||
* Tek Forum threads: | * Tek Forum threads: | ||
** [http://forum.tek.com/viewtopic.php?f=568&t=140017/ Recovering the unit from a bricked state] | ** [http://forum.tek.com/viewtopic.php?f=568&t=140017/ Recovering the unit from a bricked state] | ||
** [http://forum.tek.com/viewtopic.php?f=568&t=139999&hilit=TDS784/ Firmware updating] | ** [http://forum.tek.com/viewtopic.php?f=568&t=139999&hilit=TDS784/ Firmware updating] | ||
** [http://forum.tek.com/viewtopic.php?f=568&t=138168&hilit=TDS784/ Backing up and restoring calibration data] | ** [http://forum.tek.com/viewtopic.php?f=568&t=138168&hilit=TDS784/ Backing up and restoring calibration data] | ||
* EEVBlog Forum Threads: | |||
** [http://www.eevblog.com/forum/testgear/conversion-of-500mhz-tds744a-to-1ghz-tds784a/ Conversion of 500 MHz TDS744A to 1 GHz TDS784A] | |||
** [http://www.eevblog.com/forum/testgear/hackingupgrading-old-scope-(tds754d)/ EEVBlog Forum thread on TDS options and how to enable them] | |||
** [https://www.eevblog.com/forum/repair/unified-tektool-released-!-(firmware-flash-tools-for-old-tds-series)/ Firmware update via GPIB] | |||
* [https://simmconnlabscom.ipage.com/store/page5.html Simmconn Labs LCD replacement kits for CRT-based TDS O-scopes] | * [https://simmconnlabscom.ipage.com/store/page5.html Simmconn Labs LCD replacement kits for CRT-based TDS O-scopes] | ||
==Internals== | ==Internals== |
edits