Lavoie LA-265A: Difference between revisions

Jump to navigation Jump to search
No edit summary
Line 11: Line 11:


== Mechanically difference to 545 ==
== Mechanically difference to 545 ==
Transformer is potted.
The transformer is potted.
The ceramic terminals may be soldered with ordinarily solder  
Unlike Tektronix instruments of the same era, which require
because the terminals have tin-plated steel inserts.
silver-bearing solder, ordinary solder is fine for working on the Lavoie.
This is because the terminal strips in the Lavoie have tin-plated steel inserts.




Navigation menu