Page values for "AM503A"

"_pageData" values

1 row is stored for this page
FieldField typeValue
_creationDateDatetime2015-07-20 10:39:38 PM
_modificationDateDatetime2024-07-22 6:36:51 PM
_categoriesList of String, delimiter: |
_isRedirectBooleanNo
_pageIDInteger7,056
_pageNamePageAM503A
_pageTitleString

AM503A

_pageNamespaceInteger0

"Products" values

1 row is stored for this page
FieldField typeValue
ManufacturerPageTektronix
ModelStringAM503A
ClassStringPlug-in
DescriptionWikitext string

current probe amplifier

SeriesPageTM500 system
IntroducedText1993
DesignersList of Page, delimiter: ;Mike Mende
DiscontinuedText(?)

"Specifications" values

6 rows are stored for this page
FieldField typeValue
ParameterStringBandwidth
ValueWikitext
FieldField typeValue
ParameterStringSensitivity
ValueWikitext
  • A6302, A6312: 1 mA/Div to 5 A/Div
  • A6303: 10 mA/Div to 50 A/Div
FieldField typeValue
ParameterStringRange
ValueWikitext
  • A6302: max. 20 A continuous, 50 A peak
  • A6303: max. 100 A continuous, 500 A peak
FieldField typeValue
ParameterStringOutput
ValueWikitext

Into 50 Ω Scope, Input Set to 10 mV/div

FieldField typeValue
ParameterStringPower
ValueWikitext

17 W

FieldField typeValue
ParameterStringCompatible probes
ValueWikitext
  • A6302 (20/100 A, DC-50 MHz)
  • A6312 (20/100 A, DC-100 MHz)
  • A6303 (100/500 A, DC-15 MHz)
  • CT4 with A6302 or A6312 (2000/20000 A)