Page values for "2714"

Jump to navigation Jump to search

"_pageData" values

1 row is stored for this page
FieldField typeValue
_creationDateDatetime2017-03-16 3:19:30 AM
_modificationDateDatetime2024-05-15 6:38:49 PM
_categoriesList of String, delimiter: |Introduced in 1993 Manual needed Spectrum analyzers
_isRedirectBooleanNo
_pageIDInteger9,858
_pageNamePage2714
_pageTitleString

2714

_pageNamespaceInteger0

"Products" values

1 row is stored for this page
FieldField typeValue
ManufacturerPageTektronix
ModelString2714
ClassStringSpectrum Analyzer
DescriptionWikitext string

1.8 GHz Spectrum Analyzer

SeriesPage
IntroducedText1993
DesignersList of Page, delimiter: ;
DiscontinuedText2000

"Specifications" values

16 rows are stored for this page
FieldField typeValue
ParameterStringFrequency
ValueWikitext

9 kHz to 1.8 GHz; Preamp limited to 600 MHz

FieldField typeValue
ParameterStringFrequency Span
ValueWikitext

1 kHz/div to 100 MHz/div in 1, 2, 5 sequence (plus 0 Hz and MAX: 180 MHz/div)

FieldField typeValue
ParameterStringResolution Bandwidth
ValueWikitext

–6 dB bandwidth selections are 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz, 300 kHz, 1 MHz and 5 MHz

FieldField typeValue
ParameterStringRF Input impedance
ValueWikitext

75 Ω

FieldField typeValue
ParameterStringMaximum Safe Input Power
ValueWikitext

+70 dBmV (0.1 W or 2.2 V) continuous peak, ≤100 V DC blocking capacitor

FieldField typeValue
ParameterStringRF Attenuator
ValueWikitext

0 dB to 50 dB, 2 dB steps

FieldField typeValue
ParameterStringSensitivity
ValueWikitext

(at 300 Hz RBW) -78 dBmV (-127 dBm); -90 dBmV (-139 dBm) with preamp on

FieldField typeValue
ParameterStringReference Level
ValueWikitext

-70 dBm to +20 dBm; -23 dBmV to +66.9 dBmV

FieldField typeValue
ParameterStringSweep Speed
ValueWikitext

2 sec/Div to 1 µs/Div in 1, 2, 5 sequence

FieldField typeValue
ParameterStringTriggering Modes
ValueWikitext

Free Run, Internal, External, Line, TV Line, and TV Field

FieldField typeValue
ParameterStringDisplayed Average Noise
ValueWikitext

−66 dBm to −100 dBm

FieldField typeValue
ParameterStringDisplay Dynamic Range
ValueWikitext

80 dB

FieldField typeValue
ParameterStringDynamic Range
ValueWikitext

≥100 dBm

FieldField typeValue
ParameterStringInternal Calibrator
ValueWikitext

100 MHz marker at +18.8 dBmV (-30 dBm)

FieldField typeValue
ParameterStringPower
ValueWikitext

90 − 132 VAC, 48 to 440 Hz; 90 – 250 VAC, 48 to 63 Hz. At 115 VAC, 60 Hz, 90 W (standard), 105 W max (with options)

FieldField typeValue
ParameterStringFeatures
ValueWikitext
  • 124 kB NVRAM to save up to 108 waveform displays, 36 front panel setups, -defined key programs, and antenna factor tables.
  • Single and delta markers – readout of frequency and amplitude
  • Digital storage display
  • Acquisition modes: positive peak only, positive/negative peak, Max hold, Waterfall, an analog sweep (when digital storage is off)
  • Ensemble averaging
  • Internal preamp
  • Internal Calibrator
  • Alternate reference level units (dBm, dBmV, dBV, dBµV, dBµW, and dBµV/m)
  • Direct plot/print (Printers via Opt. 03 GPIB, or RS-232-C interface via Opt. 08).