Page values for "TG501"

Jump to navigation Jump to search

"_pageData" values

1 row is stored for this page
FieldField typeValue
_creationDateDatetime2011-10-24 3:36:35 AM
_modificationDateDatetime2024-10-11 10:48:46 AM
_categoriesList of String, delimiter: |
_isRedirectBooleanNo
_pageIDInteger1,946
_pageNamePageTG501
_pageTitleString

TG501

_pageNamespaceInteger0

"Products" values

1 row is stored for this page
FieldField typeValue
ManufacturerPageTektronix
ModelStringTG501
ClassStringPlug-in
DescriptionWikitext string

time-mark generator

SeriesPageTM500 system
IntroducedText1974
DesignersList of Page, delimiter: ;
DiscontinuedText1990

"Specifications" values

6 rows are stored for this page
FieldField typeValue
ParameterStringInterval
ValueWikitext

1 ns to 5 s in 1−2−5 sequence

FieldField typeValue
ParameterStringTiming accuracy
ValueWikitext

Stability 1×10-5, long-term drift 1×10-5 per month (with Option 1, 5×10-7 / 1×10-7 per month)

FieldField typeValue
ParameterStringError Readout
ValueWikitext

Accuracy 1 digit (±0.1% points), Range to ±7.5%

FieldField typeValue
ParameterStringAmplitude
ValueWikitext

≥1 V peak on 5 s through 10 ns; ≥750 mVp-p on 5 ns and 2 ns; ≥200 mVp-p on 1 ns (separate output) (all into 50 Ω)

FieldField typeValue
ParameterStringTrigger Output
ValueWikitext

Slaved to marker output from 5 s through 100 ns. Remains at 100 ns for all faster markers

FieldField typeValue
ParameterStringExternal Reference Input
ValueWikitext

1 MHz, 5 MHz or 10 MHz; TTL compatible (internally hard wired so output frequencies counted down to 1 MHz)