7S12: Difference between revisions
m (text) |
(template change) |
||
Line 1: | Line 1: | ||
{{Plugin Sidebar| | {{Plugin Sidebar 2| | ||
title=Tektronix 7S12| | title=Tektronix 7S12| | ||
summary=Time Domain Reflectometer / Sampler| | summary=Time Domain Reflectometer / Sampler| | ||
image=7s12-s6-s52-f.jpg| | image=7s12-s6-s52-f.jpg| | ||
caption=Tektronix 7S12 TDR/Sampler with [[S-6]] and [[S-52]] heads| | caption=Tektronix 7S12 TDR/Sampler with [[S-6]] and [[S-52]] heads| | ||
introduced=1971 | | |||
discontinued=(?) | | |||
series=[[7000-series scopes]]| | series=[[7000-series scopes]]| | ||
manuals= | manuals= | ||
Line 16: | Line 16: | ||
The 7S12 has two bays for [[:Category:7000 and 3S series sampling heads|S-series plug-in modules ("heads")]]. The right bay accepts a pulse generator or a trigger recognizer plug-in, whereas the left bay accepts a sampling plug-in. | The 7S12 has two bays for [[:Category:7000 and 3S series sampling heads|S-series plug-in modules ("heads")]]. The right bay accepts a pulse generator or a trigger recognizer plug-in, whereas the left bay accepts a sampling plug-in. | ||
The typical configuration is to have an [[S-6]] on the left and an [[S-52]] on the right for time domain reflectometry, or | The typical configuration is to have an [[S-6]] on the left and an [[S-52]] on the right for time domain reflectometry, or a sampling head like the [[S-4]] on the left and an [[S-53]] on the right as a generic sampler. | ||
The 7S12 can also control an optional [[7S11]] through its side contacts, adding a second input channel. | The 7S12 can also control an optional [[7S11]] through its left side contacts, adding a second input channel. | ||
Y axis can be scaled in voltage (mV) or distance (ρ) units, X axis in time or distance. | Y axis can be scaled in voltage (mV) or distance (ρ) units, X axis in time or distance. |
Revision as of 02:15, 23 August 2014
The Tektronix 7S12 is a Time Domain Reflectometer / Sampler plug-in for 7000-series scopes. It occupies two mainframe plug-in bays (one vertical, one horizontal).
The 7S12 has two bays for S-series plug-in modules ("heads"). The right bay accepts a pulse generator or a trigger recognizer plug-in, whereas the left bay accepts a sampling plug-in.
The typical configuration is to have an S-6 on the left and an S-52 on the right for time domain reflectometry, or a sampling head like the S-4 on the left and an S-53 on the right as a generic sampler.
The 7S12 can also control an optional 7S11 through its left side contacts, adding a second input channel.
Y axis can be scaled in voltage (mV) or distance (ρ) units, X axis in time or distance.
Specifications
Key Specifications
Sweep modes | Single / Repetitive / Manual / External input |
---|---|
With S-6 and S-52 |
|
Sweep modes |
|
Weight | 2.13 kg (4.7 lbs) |
Links
- http://www.barrytech.com/tektronix/tek7000/tek7s12.html
- Tek 7S12 page at amplifier.cd
- Evaluation of 7S12 performance (video)
- 7S12 extender board by Dave Partridge
Pictures
-
Front view without sampling head plug-ins
-
7S12 TDR "self portrait" in 7613 storage mainframe
Inside
-
Left side
-
Left side with cover. Side contacts to interface 7S11 are exposed.
-
Right side
-
Top view
-
Horizontal board
-
Vertical board
Measurements
-
TDR "Self Portrait" — pulse reflected on S-6 "through" path (approx. 120 ps one way)
-
7S12 displaying the incident pulse from an S-52 (nom. < 25 ps) through an S-6 head (nom. < 30 ps). Displayed rise time ~35 ps confirms spec.
-
7S12/S-6/S-52 displaying pulse reflection from ~ 5 in semi-rigid SMA cable. Stored display of two traces. Left trace: cable only, right trace: cable plus SMA-to-BNC adapter (~ 25 mm)
-
7S12/S-6/S-52 displaying reflected pulse from end of 5 in semi-rigid SMA cable. Stored display overlaying multiple traces, left to right: cable alone, SMA-to-BNC adapter added, BNC f-f adapter added, (cheap) 50 Ω terminator added.