Electrolytic repair 1.jpg | Remove defective cap
Electrolytic repair 1.jpg | Remove defective cap
Electrolytic repair 2.jpg | Cut can near base, remove guts
Electrolytic repair 2.jpg | Cut can near base (using a small hacksaw or a pipe cutter), remove guts
Electrolytic repair 3.jpg | Fit modern cap
Electrolytic repair 3.jpg | Fit modern cap
Electrolytic repair 4.jpg | Epoxy cap onto base
Electrolytic repair 4.jpg | Epoxy cap onto base
Line 15: Line 15:
:'''Symptom:''' No trace, HV low despite maximum setting
:'''Symptom:''' No trace, HV low despite maximum setting
:'''Root cause:''' HV [[Bumble Bee capacitors|PIO "Bumble Bee" capacitors]] leaky (~180 μA at 2 kV); no trace because CRT grid too negative wrt. cathode
:'''Root cause:''' HV [[Bumble Bee capacitors|PIO "Bumble Bee" capacitors]] leaky (~180 μA at 2 kV); no trace because CRT grid too negative wrt. cathode
:'''Solution:''' Replace caps
:'''Solution:''' Replace caps with modern ceramic equivalents
:<gallery>
:<gallery>
585 HV caps old.jpg | old PIO caps in place
585 HV caps old.jpg | old PIO caps in place
Line 30: Line 30:
:'''Symptom:''' Trace fading after ~10 minutes operation
:'''Symptom:''' Trace fading after ~10 minutes operation
:'''Root cause:''' HV resonant cap (C808) leaky, overheating (visible bulge)
:'''Root cause:''' HV resonant cap (C808) leaky, overheating (visible bulge)
:'''Solution:''' Replace cap
:'''Solution:''' Replace cap with modern ceramic equivalent
:<gallery>
:<gallery>
585-c808-therm.jpg | Thermal image
585-c808-therm.jpg | Thermal image
Line 42: Line 42:
:<gallery>
:<gallery>
585-neon-1.jpg | broken lead
585-neon-1.jpg | broken lead
585-neon-2.jpg | repaired leads (before encapsulation with epoxy)
585-neon-2.jpg | repaired leads (before cleaning and epoxy encapsulation)
</gallery>
</gallery>
:--[[User:Peter|Peter]] ([[User talk:Peter|talk]]) 02:45, 4 May 2019 (PDT)
:--[[User:Peter|Peter]] ([[User talk:Peter|talk]]) 02:45, 4 May 2019 (PDT)
==Wavy trace ==
:'''Symptom:''' Wavy trace
:'''Root cause:''' C786 (100 µF 25 V) has high internal resistance (ESR ~ 20 Ω) causing +12.6 V regulator circuit to oscillate
:'''Solution:''' Replace C786 with new part.
:<gallery>
585 wavy trace.JPG | wavy trace
585_wavy_trace_new_electrolytics.JPG |  +12.6 v PSU with  new eletrolytics.
</gallery>
:--[[User:Matt|Matt]] ([[User talk:Matt|Matt]]) 08:53, 5 May 2019 (PDT)




[[Category:Instrument repair reports]]