1M1: Difference between revisions
m (→top: clean up, replaced: title=Tektronix → manufacturer=Tektronix | model=) |
No edit summary |
||
Line 1: | Line 1: | ||
{{Plugin Sidebar | {{Plugin Sidebar | | ||
manufacturer=Tektronix | model=1M1 | | |manufacturer=Tektronix | ||
summary=Calibration plug-in | | |series=500-series scopes | ||
image=Tek 1m1 front.jpg | | |model=1M1 | ||
caption=Tek 1M1 | |summary=Calibration plug-in | ||
|image=Tek 1m1 front.jpg | |||
introduced=1964 | | |caption=Tek 1M1 | ||
discontinued=(?) | | |introduced=1964 | ||
manuals= | |discontinued=(?) | ||
|designers= | |||
|manuals= | |||
* [[Media:070-0407-01.pdf|Tektronix 067-0521-00 Manual (PDF)]] | * [[Media:070-0407-01.pdf|Tektronix 067-0521-00 Manual (PDF)]] | ||
* [[Media:070-0407-02.pdf|Tektronix 067-0521-01 Manual (PDF)]] | * [[Media:070-0407-02.pdf|Tektronix 067-0521-01 Manual (PDF)]] | ||
Line 17: | Line 19: | ||
* [[Media:Tek tu-7 irb.pdf|Tektronix TU-7 Instrument Reference Book (PDF, OCR)]] | * [[Media:Tek tu-7 irb.pdf|Tektronix TU-7 Instrument Reference Book (PDF, OCR)]] | ||
* [[Media:Tek 067-0521-00 fcp july 1969.pdf|Tektronix 067-0521-00 Factory Calibration Procedure, July 1969]] | * [[Media:Tek 067-0521-00 fcp july 1969.pdf|Tektronix 067-0521-00 Factory Calibration Procedure, July 1969]] | ||
}} | }} | ||
The '''Tektronix [[TU-7]]/1M1/[[067-0521-00]]''' is a [[Letter-series_and_1-series_plug-ins|letter series plug-in]] | The '''Tektronix [[TU-7]]/1M1/[[067-0521-00]]''' is a [[Letter-series_and_1-series_plug-ins|letter series plug-in]] used for calibrating [[500-series scopes]]. | ||
used for calibrating [[500-series scopes]]. | |||
It is a multifunction replacement for the [[P|Type P Pulser]], the [[TU-2|TU-2 Test Load]], | It is a multifunction replacement for the [[P|Type P Pulser]], the [[TU-2|TU-2 Test Load]], and the [[EP-53|EP-53 Gain Set Adaptor]]. | ||
and the [[EP-53|EP-53 Gain Set Adaptor]]. | |||
It is used for calibrating the mainframe's step response and gain, | It is used for calibrating the mainframe's step response and gain, checking dual-trace operation, common mode rejection, and power supply regulation. | ||
checking dual-trace operation, common mode rejection, and power supply regulation. | |||
(500-series mainframes are designed to have | (500-series mainframes are designed to have 10 div/Volt response to differential signals from the plug-in, and zero response to common-mode signals.) | ||
10 div/Volt response to differential signals from the plug-in, | |||
and zero response to common-mode signals.) | |||
It contains a transistor multivibrator whose output is sharpened | It contains a transistor multivibrator whose output is sharpened through Tek-made Gallium-Arsenide diodes (later production used silicon), a dual-trace circuit using [[12AT7]] and [[6AL5]] tubes, and various load resistors. | ||
through Tek-made Gallium-Arsenide diodes (later production used silicon), | |||
a dual-trace circuit using [[12AT7]] and [[6AL5]] tubes, and various load resistors. | |||
It does not have the Type P's short operating life because it does not use a [[mercury switch]]. | It does not have the Type P's short operating life because it does not use a [[mercury switch]]. | ||
This instrument went through several names. | This instrument went through several names. At its [[introduced in 1964|1964]] introduction, it was the '''TU-7'''. | ||
At its [[introduced in 1964|1964]] introduction, it was the '''TU-7'''. | Some early Tek-internal instruments for design, manufacturing, and calibration had TU (Test Unit) nomenclature. | ||
Some early Tek-internal instruments for design, | (Other examples include the [[TU-75B]] Variac, the TU-?? dim-bulb fixture, and the [[TU-50]] sine/square/pulse generator.) | ||
manufacturing, and calibration had TU (Test Unit) nomenclature. | |||
(Other examples include the [[TU-75B]] Variac, the TU-?? dim-bulb fixture, | |||
and the [[TU-50]] sine/square/pulse generator.) | |||
In 1965, it was renamed '''Type 1M1''' to fit into the letter-series nomenclature like its predecessor. | In 1965, it was renamed '''Type 1M1''' to fit into the letter-series nomenclature like its predecessor. |
Revision as of 08:57, 13 August 2021
The Tektronix TU-7/1M1/067-0521-00 is a letter series plug-in used for calibrating 500-series scopes.
It is a multifunction replacement for the Type P Pulser, the TU-2 Test Load, and the EP-53 Gain Set Adaptor.
It is used for calibrating the mainframe's step response and gain, checking dual-trace operation, common mode rejection, and power supply regulation.
(500-series mainframes are designed to have 10 div/Volt response to differential signals from the plug-in, and zero response to common-mode signals.)
It contains a transistor multivibrator whose output is sharpened through Tek-made Gallium-Arsenide diodes (later production used silicon), a dual-trace circuit using 12AT7 and 6AL5 tubes, and various load resistors. It does not have the Type P's short operating life because it does not use a mercury switch.
This instrument went through several names. At its 1964 introduction, it was the TU-7. Some early Tek-internal instruments for design, manufacturing, and calibration had TU (Test Unit) nomenclature. (Other examples include the TU-75B Variac, the TU-?? dim-bulb fixture, and the TU-50 sine/square/pulse generator.)
In 1965, it was renamed Type 1M1 to fit into the letter-series nomenclature like its predecessor. Later still, the 067- calibration fixture naming system took hold and it was rechristened 067-0521-00.
The instrument was also revised once - more pulse frequencies - and the name upgraded to 067-0521-01.
It does not appear - under any name - in any Tek catalog, but the 1964 catalog does list a cousin: Type 10/11M1, for the Type 647 scope.
Links
- 067-0521-01 @ radiomuseum.org
Pictures
-
-
-
-
-
TU-7 variant with five repetition rates
-
TU-7 variant with five repetition rates
-
TU-7 variant with five repetition rates
-
TU-7 variant with five repetition rates
-
TU-7 variant with five repetition rates
-
067-0521-01 Front
-
067-0521-01 LHS
-
067-0521-01 RHS
-
067-0521-01 Top
-
067-0521-01 Bottom
-
067-0521-01 Schottky Diodes (pulse generator)
-
067-0521-01 Vertical amp step response test on a 547
-
067-0521-01 Chopped trace test signal