TCP202: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
[[ | {{Probe Sidebar | ||
|manufacturer=Tektronix | |||
|model=TCP202 | |||
|summary=50 MHz, 15 A current probe | |||
|image=tcp202-1.jpg | |||
|caption=Tektronix TCP202 | |||
|for=Tekprobe BNC connector | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:070-9543-02.pdf|Tektronix TCP202 Reference]] | |||
* [[Media:070-9542-03.pdf|Tektronix TCP202 Manual -03]] | |||
* [[Media:070-9542-02.pdf|Tektronix TCP202 Manual -02]] | |||
* [[Media:070-9542-00.pdf|Tektronix TCP202 Manual -00]] | |||
* [[Media:51W-10736-0.pdf|TCP202 Data Sheet]] | |||
* [[Media:51W-10798-1.pdf|TCP202 Sales Brochure]] | |||
}} | |||
The '''Tektronix TCP202''' is a DC coupled current probe with a 50 MHz bandwidth and 15 A maximum current. | The '''Tektronix TCP202''' is a DC coupled current probe with a 50 MHz bandwidth and 15 A maximum current. | ||
It has a [[Tekprobe BNC connector]] and requires a compatible oscilloscope or [[1103]] PSU to power it. | It has a [[Tekprobe BNC connector]] and requires a compatible oscilloscope or [[1103]] PSU to power it. | ||
{{ | {{BeginSpecs}} | ||
{{Spec | Bandwidth | DC to 50 MHz }} | |||
{{Spec | Rise time | ≤7 ns }} | |||
{{Spec | Propagation time | 17 ns }} | |||
{{Spec | Max current | 15 A DC, 50 A peak AC }} | |||
{{Spec | Sensitivity | 10 mA/Div min. }} | |||
{{Spec | Max. conductor diameter | 3.8 mm }} | |||
{{Spec | Insertion impedance | 2 mΩ @ 1 kHz, 100 mΩ @ 5 MHz }} | |||
{{EndSpecs}} | |||
==Pictures== | ==Pictures== |
Latest revision as of 10:08, 15 October 2022
The Tektronix TCP202 is a DC coupled current probe with a 50 MHz bandwidth and 15 A maximum current.
It has a Tekprobe BNC connector and requires a compatible oscilloscope or 1103 PSU to power it.
Key Specifications
Bandwidth | DC to 50 MHz |
---|---|
Rise time | ≤7 ns |
Propagation time | 17 ns |
Max current | 15 A DC, 50 A peak AC |
Sensitivity | 10 mA/Div min. |
Max. conductor diameter | 3.8 mm |
Insertion impedance | 2 mΩ @ 1 kHz, 100 mΩ @ 5 MHz |