1M1: Difference between revisions

From TekWiki
Jump to navigation Jump to search
mNo edit summary
(duplicate docs removed; BAMA copy = 070-407;)
Line 10: Line 10:
|designers=
|designers=
|manuals=
|manuals=
* [[Media:070-0407-01.pdf|Tektronix 067-0521-00 Manual]]
* [[Media:070-407.pdf|Tektronix TU-7 Manual]] (070-407; rough scan, OCR)
* [[Media:070-0407-02.pdf|Tektronix 067-0521-01 Manual]]
* [[Media:070-0407-01.pdf|070-0407-01 Tektronix 067-0521-00 Manual]] (070-0407-01; OCR)
* [https://w140.com/tek_tu-7_rough.pdf Tektronix TU-7 Manual] (rough scan, OCR)
* [[Media:070-0407-02.pdf|070-0407-02 Tektronix 067-0521-01 Manual]] (070-0407-02; OCR)
* [https://bama.edebris.com/manuals/tek/tu7 1M1 / TU-7 / 067-0521-00 Manual on BAMA]
* [[Media:067-0521-00.pdf|Tektronix 067-0521-00]] (bad-OCR)
* [[Media:067-0521-01.pdf|Tektronix 067-0521-01]] (bad-OCR)
* [[Media:bama_manuals_tek_1m1_tu-7.pdf|1M1 / TU-7 / 067-0521-00 Manual on BAMA]] (bad-OCR)
* [[Media:Tek tu-7 irb.pdf|Tektronix TU-7 Instrument Reference Book]] (OCR)
* [[Media:Tek tu-7 irb.pdf|Tektronix TU-7 Instrument Reference Book]] (OCR)
* [[Media:Tek 067-0521-00 fcp july 1969.pdf|Tektronix 067-0521-00 Factory Calibration Procedure, July 1969‎]]
* [[Media:Tek 067-0521-00 fcp july 1969.pdf|Tektronix 067-0521-00 Factory Calibration Procedure, July 1969‎]]
Line 28: Line 24:
(500-series mainframes are designed to have 10 div/Volt response to differential signals from the plug-in, and zero response to common-mode signals.)
(500-series mainframes are designed to have 10 div/Volt response to differential signals from the plug-in, and zero response to common-mode signals.)


It contains a transistor multivibrator whose output is sharpened through Tek-made Gallium-Arsenide diodes (later production used silicon), a dual-trace circuit using [[12AT7]] and [[6AL5]] tubes, and various load resistors.
It contains a transistor multivibrator whose output is sharpened through Tek-made Gallium-Arsenide diodes (later production used silicon), a dual-trace circuit using [[12AT7]] and [[6AL5]] tubes, and various load resistors. It does not have the Type P's short operating life because it does not use a [[mercury switch]].
It does not have the Type P's short operating life because it does not use a [[mercury switch]].


This instrument went through several names. At its [[introduced in 1964|1964]] introduction, it was the '''TU-7'''.   
This instrument went through several names. At its [[introduced in 1964|1964]] introduction, it was the '''TU-7'''.   
Some early Tek-internal instruments for design, manufacturing, and calibration had TU (Test Unit) nomenclature.   
Some early Tek-internal instruments for design, manufacturing, and calibration had TU (Test Unit) nomenclature.   
(Other examples include the [[TU-75B]] Variac, the TU-?? dim-bulb fixture, and the [[TU-50]] sine/square/pulse generator.)   
(Other examples include the [[TU-75B]] Variac, and the [[TU-50]] sine/square/pulse generator.)   


In 1965, it was renamed '''Type 1M1''' to fit into the letter-series nomenclature like its predecessor.   
In 1965, it was renamed '''Type 1M1''' to fit into the letter-series nomenclature like its predecessor.   

Revision as of 08:06, 26 January 2023

Tektronix 1M1
Calibration plug-in
Tek 1M1

Compatible with 500-series scopes

Produced from 1964 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix TU-7/1M1/067-0521-00 is a letter series plug-in used for calibrating 500-series scopes.

It is a multifunction replacement for the Type P Pulser, the TU-2 Test Load, and the EP-53 Gain Set Adaptor.

It is used for calibrating the mainframe's step response and gain, checking dual-trace operation, common mode rejection, and power supply regulation.

(500-series mainframes are designed to have 10 div/Volt response to differential signals from the plug-in, and zero response to common-mode signals.)

It contains a transistor multivibrator whose output is sharpened through Tek-made Gallium-Arsenide diodes (later production used silicon), a dual-trace circuit using 12AT7 and 6AL5 tubes, and various load resistors. It does not have the Type P's short operating life because it does not use a mercury switch.

This instrument went through several names. At its 1964 introduction, it was the TU-7. Some early Tek-internal instruments for design, manufacturing, and calibration had TU (Test Unit) nomenclature. (Other examples include the TU-75B Variac, and the TU-50 sine/square/pulse generator.)

In 1965, it was renamed Type 1M1 to fit into the letter-series nomenclature like its predecessor. Later still, the 067- calibration fixture naming system took hold and it was rechristened 067-0521-00.

The instrument was also revised once - more pulse frequencies - and the name upgraded to 067-0521-01.

It does not appear - under any name - in any Tek catalog, but the 1964 catalog does list a cousin: Type 10/11M1, for the Type 647 scope.