1X2: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
(please do not include parent categories - see Tekwiki Guidelines)
 
(13 intermediate revisions by 4 users not shown)
Line 1: Line 1:
The 1X2 is a high-voltage rectifier tube with a maximum inverse voltage of 15kV
{{Vacuum Tube
a maximum forward current of 1mA.  The filament operates on 1.25V.
|Type=Diode
|Number=1X2
|EuroNumber=DY80
|RussianNumber=
|Part_nos=154-0005-00
|Description=high-voltage rectifier
|Used_in=420;507;565;
|Designers=
}} with a {{B9A base}} and an anode cap.


* [http://w140.com/1X2.pdf 1X2 Preliminary Datasheet (PDF)]
Its maximum inverse voltage is 15 kV and the maximum forward current is 1 mA.  The filament operates on 1.25 V, 200 mA.
 
==Used in==
The 1X2 tube is used in the [[565]], [[507]], and [[517]] ([[420]] HV supply).
 
{| class="wikitable"
{{Checkedtubes TableHeader}}
|-
|  [[420]], [[420A]] || 157-0079-00  || All, Note 1   
|}
 
Note 1: A dot of yellow lacquer is applied to bottom of the selected tube.
 
{{Tube aging reference}}
{{Part usage}}
 
==Links==
* [https://w140.com/1X2.pdf 1X2 Preliminary Datasheet]
* [[tube:1x2|1X2]] @ radiomuseum.org
 
==Pictures==
<gallery>
Raytheon 1x2a 1.jpg | Raytheon 1X2A
Raytheon 1x2a 2.jpg | Raytheon 1X2A
Raytheon 1x2a 3.jpg | Raytheon 1X2A
Tek rm565 hv rectifier.jpg| 1X2 Vacuum Tube in the [[565|RM565]] HV Power Supply
420A 1.JPG|Five 1X2 Vacuum Tubes in the [[420|Type 420]] HV Power Supply ([[517]] scope)
</gallery>


[[Category:Diode tubes]]
[[Category:Diode tubes]]

Latest revision as of 02:24, 19 September 2023

The 1X2  (European: DY80) (P/N 154-0005-00) is a high-voltage rectifier vacuum tube with a B9A (Noval) miniature 9-pin base and an anode cap.

Its maximum inverse voltage is 15 kV and the maximum forward current is 1 mA. The filament operates on 1.25 V, 200 mA.

Used in

The 1X2 tube is used in the 565, 507, and 517 (420 HV supply).

Aged/Checked/Matched Pair Details
Used in Tek Part# S/N Range
420, 420A 157-0079-00 All, Note 1

Note 1: A dot of yellow lacquer is applied to bottom of the selected tube.

Reference:

Tube aging procedure / Selection and checking procedure

Some instruments using part 1X2

Instrument Manufacturer Class Model Description Introduced
420 Tektronix Power supply 420 high-voltage power supply 1950
507 Tektronix Oscilloscope 507 Power Industry scope 1959
565 Tektronix Oscilloscope 565 10 MHz dual-beam scope 1962

Links

Pictures