P6015: Difference between revisions
(first in 1963 catalog) |
No edit summary |
||
(8 intermediate revisions by 3 users not shown) | |||
Line 7: | Line 7: | ||
|for=1 MΩ scope inputs | |for=1 MΩ scope inputs | ||
|introduced=1963 | |introduced=1963 | ||
|discontinued= | |discontinued=1990 | ||
|manuals= | |manuals= | ||
* [[Media:070-0373-01.pdf|P6015 | * [[Media:070-0373-01.pdf|P6015 manual 070-0373-01 (1963)]] | ||
* [[Media:070-0373-02.pdf|P6015 | * [[Media:070-0373-02.pdf|P6015 manual 070-0373-02 (1985)]] | ||
* [[Media:070- | * [[Media:070-0373-02 rev 1990.pdf|P6015 manual 070-0373-02 (1990)]] | ||
* [[Media:Tek_p6007_p6009_p6015_cat.pdf|P6007 P6009 P6015 Catalog Description]] | * [[Media:Tek_p6007_p6009_p6015_cat.pdf|P6007 P6009 P6015 Catalog Description]] | ||
}} | }} | ||
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse). | The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse). | ||
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the [[P6013]] predecessor model. | It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the [[P6013]] predecessor model. | ||
The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its [[wikipedia:Montreal Protocol|ozone-depleting properties]]. For this reason, it was replaced by the [[P6015A]] [[introduced in 1991|in 1991]], which uses a silicone based replacement. | |||
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants. | The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants, which was available with [[PL-259]] or [[BNC]] plugs on the scope side (termination box part numbers 015-039/015-0039-00 and 015-049/015-0049-00, respectively). | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 39: | Line 36: | ||
==Links== | ==Links== | ||
* [[Patent US 3256484A|US Patent 3,256,484; ''High voltage test probe containing a part gas, part liquid dielectric fluid under pressure and having a transparent housing section for viewing the presence of the liquid therein'']]. Paul V Terry, 1962. | * [[Patent US 3256484A|US Patent 3,256,484; ''High voltage test probe containing a part gas, part liquid dielectric fluid under pressure and having a transparent housing section for viewing the presence of the liquid therein'']]. Paul V Terry, 1962. | ||
* [http://www.barrytech.com/tektronix/probes/tekp6015.html P6015 @ barrytech.com] | * [http://www.barrytech.com/tektronix/probes/tekp6015.html P6015 @ barrytech.com] | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek P6015 box.jpg | Tektronix P6015 in box | Tek P6015 box.jpg | Tektronix P6015 in box | ||
Tek P6015 box closed.jpg | |||
Tek_P6015_1.jpg | Tek_P6015_1.jpg | ||
Tek_P6015_2.jpg | Tek_P6015_2.jpg | ||
Line 50: | Line 47: | ||
Tek_P6015_4.jpg | Tek_P6015_4.jpg | ||
P6015 BW.png | P6015 BW.png | ||
Tek p6015 schem.png | Tek p6015 schem.png | schematic <br> old version | ||
Tek P6015 derating.jpg | Derating curves | Tek P6015 derating.jpg | Derating curves | ||
P6015_Freon_Can.jpg | Can of Freon Dielectric Fluid | |||
Tek P6015 term box.jpg | Termination box | Tek P6015 term box.jpg | Termination box <br> new version | ||
</gallery> | </gallery> | ||
[[Category:1 MΩ Oscilloscope probes]] | [[Category:1 MΩ Oscilloscope probes]] | ||
[[Category:High voltage oscilloscope probes]] | [[Category:High voltage oscilloscope probes]] |
Latest revision as of 03:03, 21 October 2023
The Tektronix P6015 is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the P6013 predecessor model. The original filling material, Freon-114 aka Fluorocarbon 114 (R-114, CFC-114), is no longer available due to its ozone-depleting properties. For this reason, it was replaced by the P6015A in 1991, which uses a silicone based replacement.
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants, which was available with PL-259 or BNC plugs on the scope side (termination box part numbers 015-039/015-0039-00 and 015-049/015-0049-00, respectively).
Key Specifications
Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) |
---|---|
Risetime | 4.67 ns (10' cable), 14 ns (25' cable) |
Attenuation | 1000× |
Input impedance | 100 MΩ // 3 pF |
Compensation range | 15-50 pF |
Max. input voltage |
|
Links
- US Patent 3,256,484; High voltage test probe containing a part gas, part liquid dielectric fluid under pressure and having a transparent housing section for viewing the presence of the liquid therein. Paul V Terry, 1962.
- P6015 @ barrytech.com
Pictures
-
Tektronix P6015 in box
-
-
-
-
-
-
-
schematic
old version -
Derating curves
-
Can of Freon Dielectric Fluid
-
Termination box
new version