|manufacturer=Tektronix | |||
summary = 3 GHz High Impedance Probe Sampler | |series=11800-series scopes | ||
|type=SD-20 | |||
image=Sd 14.jpg | | |summary=3 GHz High Impedance Probe Sampler | ||
caption=Tektronix SD-14 | | |image=Sd 14.jpg | ||
introduced = | |caption=Tektronix SD-14 | ||
discontinued = (?) | | |introduced=1991 | ||
manuals= | |discontinued=(?) | ||
* [ | |designers= | ||
* [ | |manuals= | ||
* [[Media:070-8286-01.pdf|Tektronix SD-14 User Manual]] | |||
* [[Media:070-8285-01.pdf|Tektronix SD-14 Service Manual]] | |||
* [[Media:063-2011-01.pdf|Tektronix SD-14 Opt 01 Instructions]] | |||
}} | }} | ||
The '''Tektronix SD-14 High Impedance Probe Sampler''' is a dual-channel, 3 GHz probe sampler designed for high-impedance (100 kΩ) signal acquisition. | The '''Tektronix SD-14 High Impedance Probe Sampler''' is a dual-channel, 3 GHz probe sampler designed for high-impedance (100 kΩ) signal acquisition. | ||
Line 19: | Line 22: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Rise time | <140 ps}} | |||
{{Spec | Bandwidth | 3 GHz typical}} | |||
{{Spec | Input impedance | 100 kΩ // 0.5 pF }} | {{Spec | Input impedance | 100 kΩ // 0.5 pF }} | ||
{{Spec | Dynamic range | 7 V (±3.5 V offset) }} | {{Spec | Dynamic range | 7 V (±3.5 V offset) }} | ||
{{Spec | Maximum safe input voltage | ±15 V dc + peak ac }} | |||
{{Spec | Time matching range | 350 ps}} | |||
{{Spec | Displayed noise | 8 mV<sub>RMS</sub> max}} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
==Pictures== | ==Pictures== | ||
Line 33: | Line 40: | ||
[[Category:11800 series sampling plugins]] | [[Category:11800 series sampling plugins]] | ||
Latest revision as of 03:58, 24 October 2023
The Tektronix SD-14 High Impedance Probe Sampler is a dual-channel, 3 GHz probe sampler designed for high-impedance (100 kΩ) signal acquisition.
It consists of two samplers, each attached at the end of a 1-meter cable. Applications include high-speed device characterization such as ECL, CMOS, ACL and GaAs testing. Option 01 adds a longer probe tip, two probe-to-board adapters, and two probe-to-SMB adapters. These ease probing of plated holes (as found in Outboards for IC testers) and semi-permanent connections.
In conjunction with the 11801C and SM-11 multi-channel unit, it is possible to configure up to 136 channels of high-impedance acquisition with accuracy approaching 140 ps.
Key Specifications
Rise time | <140 ps |
---|---|
Bandwidth | 3 GHz typical |
Input impedance | 100 kΩ // 0.5 pF |
Dynamic range | 7 V (±3.5 V offset) |
Maximum safe input voltage | ±15 V dc + peak ac |
Time matching range | 350 ps |
Displayed noise | 8 mVRMS max |