442: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
m (refreshed pdfs) |
||
(14 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar | | {{Oscilloscope Sidebar | ||
|manufacturer=Tektronix | |||
summary=35 MHz dual-trace scope | | |series=400-series scopes | ||
image=Tek 442 1.jpg | | |model=442 | ||
caption=Tek 442 | | |summary=35 MHz dual-trace scope | ||
introduced=(?) | | |image=Tek 442 1.jpg | ||
discontinued=(?) | | |caption=Tek 442 | ||
manuals= | |introduced=(?) | ||
* [ | |discontinued=(?) | ||
* [ | |designers= | ||
|manuals= | |||
* [[Media:070-2373-00.pdf | Tektronix 442 Operators Manual ]] (low resolution) | |||
* [[Media:070-2374-01.pdf | Tektronix 442 Service Manual ]] | |||
}} | }} | ||
The '''Tektronix 442''' is a 35 MHz dual-trace oscilloscope with a single timebase. | The '''Tektronix 442''' is a 35 MHz dual-trace oscilloscope with a single timebase. | ||
Line 16: | Line 18: | ||
[[Category:Specifications needed]] ''please add'' | [[Category:Specifications needed]] ''please add'' | ||
The anode voltage on the CRT is | The anode voltage on the CRT is 10 kV and the standard [[phosphor]] was P31. | ||
A Tektronix 442 consumes 36 watts and weighs about 20 pounds. | A Tektronix 442 consumes 36 watts and weighs about 20 pounds. | ||
Line 22: | Line 24: | ||
==Internals== | ==Internals== | ||
Serials numbers from B010100 to B010786 use the [[154-0729-00]] CRT. | Serials numbers from B010100 to B010786 use the [[154-0729-00]] CRT. | ||
Starting with serial number B010787, the 154-0804-00 CRT is used. | Starting with serial number B010787, the [[154-0804-00]] CRT is used. | ||
Triggering is done using a trigger amplifier made of discrete bipolar transistors and | Triggering is done using a trigger amplifier made of discrete bipolar transistors and | ||
Line 45: | Line 47: | ||
Tek 442 3.jpg | Tek 442 3.jpg | ||
Tek 442 4.jpg | Tek 442 4.jpg | ||
Tek 442 rear.jpg | |||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|442}} | |||
[[Category:400 series scopes]] | [[Category:400 series scopes]] |
Latest revision as of 12:00, 29 November 2023
The Tektronix 442 is a 35 MHz dual-trace oscilloscope with a single timebase.
Specifications
please add
The anode voltage on the CRT is 10 kV and the standard phosphor was P31.
A Tektronix 442 consumes 36 watts and weighs about 20 pounds.
Internals
Serials numbers from B010100 to B010786 use the 154-0729-00 CRT. Starting with serial number B010787, the 154-0804-00 CRT is used.
Triggering is done using a trigger amplifier made of discrete bipolar transistors and a 74S00 TTL quad NAND gate configured as a flip-flop.
The power supply is linear and regulated using op amps as error amplifiers.
The vertical and horizontal amplifiers are made of discrete bipolar transistors except for the dual-JFETs that are used as high-impedance buffers at the signal inputs.
Links
Pictures
Components
Some Parts Used in the 442
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
154-0729-00 | 154-0729-00 | CRT | CRT | T921 • T922 • T922R • T932 • T932A • T935 • T935A • 442 |
154-0804-00 | 154-0804-00 | CRT | CRT | 442 • T922 |