[[ | {{Probe Sidebar | ||
The '''Tektronix P6040/CT-1''' is a | |manufacturer=Tektronix | ||
|model=P6040 | |||
|summary=AC current probe | |||
|for=50 Ω scope inputs | |||
|image=Tek_CT-1_1.jpg | |||
|caption=P6040/CT-1 current probe | |||
|introduced=1963 | |||
|discontinued=(?) | |||
|designers= | |||
|manuals= | |||
* [[Media:070-0375-01.pdf|Tektronix CT-1/P6040 Manual]] | |||
* [[Media:Tek_p6040_ct-1_1971_cat.pdf|Description of P6040 and CT-1 in 1971 Catalog]] | |||
}} | |||
The '''Tektronix P6040/CT-1''' is a 35 kHz – 1 GHz current probe intended for sampling scopes. | |||
* '''015-0041-00''' is the part number for the CT-1/P6040 combination | |||
* '''010-0133-00''' is the part number for the P6040 alone | |||
* '''015-0040-00''' is the part number for the CT-1 alone | |||
{{BeginSpecs}} | The P6040 is an 18", 50 Ω cable with a [[GR-874 connector]] for the scope end (e.g. [[S-1]], [[3S6]]) and an [[SMB]] connector on the other end to connect to one of possibly several [[CT-1]] transformers installed in a circuit to be tested. | ||
{{BeginSpecs}} for the CT-1 | |||
{{Spec | Sensitivity | 5 mV/mA into 50 Ω }} | {{Spec | Sensitivity | 5 mV/mA into 50 Ω }} | ||
{{Spec | Rise time | <350 ps }} | {{Spec | Rise time | <350 ps }} | ||
{{Spec | Frequency response | 35 kHz to 1 GHz (-30%) }} | {{Spec | Frequency response | 35 kHz to 1 GHz (-30%) }} | ||
{{Spec | Max. current | 500 mA RMS, 100 A peak }} | {{Spec | Max. current | 500 mA<sub>RMS</sub>, 100 A peak }} | ||
{{Spec | Input Aperture | ≥0.065" (1.6 mm) }} | |||
{{Spec | Voltage Rating | 1000 V }} | |||
{{Spec | Insertion Impedance | Terminated: 1 Ω // 5 μH, Un-terminated: 2 Ω // 5 μH }} | |||
{{Spec | Capacitive Loading | 0.5 to 1.5 pF }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek p6040 1.jpg | Tek p6040 1.jpg | ||
Line 26: | Line 44: | ||
Tek_CT-1_3.jpg | Tek_CT-1_3.jpg | ||
Tek_CT-1_4.jpg | Tek_CT-1_4.jpg | ||
P6040-CT1.jpg | |||
Tek 015-040 1.JPG | Early CT-1 | |||
Tek 015-040 2.JPG | Early CT-1 | |||
</gallery> | </gallery> | ||
[[Category:Oscilloscope current probes]] | [[Category:Oscilloscope current probes]] | ||
Latest revision as of 20:02, 29 November 2023
The Tektronix P6040/CT-1 is a 35 kHz – 1 GHz current probe intended for sampling scopes.
- 015-0041-00 is the part number for the CT-1/P6040 combination
- 010-0133-00 is the part number for the P6040 alone
- 015-0040-00 is the part number for the CT-1 alone
The P6040 is an 18", 50 Ω cable with a GR-874 connector for the scope end (e.g. S-1, 3S6) and an SMB connector on the other end to connect to one of possibly several CT-1 transformers installed in a circuit to be tested.
Key Specifications
Sensitivity | 5 mV/mA into 50 Ω |
---|---|
Rise time | <350 ps |
Frequency response | 35 kHz to 1 GHz (-30%) |
Max. current | 500 mARMS, 100 A peak |
Input Aperture | ≥0.065" (1.6 mm) |
Voltage Rating | 1000 V |
Insertion Impedance | Terminated: 1 Ω // 5 μH, Un-terminated: 2 Ω // 5 μH |
Capacitive Loading | 0.5 to 1.5 pF |
Pictures
-
-
-
-
-
-
-
-
-
-
-
-
Early CT-1
-
Early CT-1