2205: Difference between revisions
No edit summary |
No edit summary |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 10: | Line 10: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:070-6717-00.pdf|Tektronix 2205 Operators Manual]] (bad-OCR) | |||
* [[Media:070-6716-00.pdf|Tektronix 2205 Service Manual]] (bad-OCR) | |||
* ''2205-40 manual needed [[Category:Manual needed]]'' | |||
<!-- | |||
* [http://w140.com/tek_2205.pdf Tektronix 2205 Service Manual (PDF)] | * [http://w140.com/tek_2205.pdf Tektronix 2205 Service Manual (PDF)] | ||
* [http://w140.com/tek_2205_operators.pdf Tektronix 2205 Operators Manual (PDF)] | * [http://w140.com/tek_2205_operators.pdf Tektronix 2205 Operators Manual (PDF)] | ||
--> | |||
}} | }} | ||
The '''Tektronix 2205''' is a 20 MHz dual-trace analog oscilloscope. | The '''Tektronix 2205''' is a 20 MHz dual-trace analog oscilloscope [[introduced in 1989]]. There is a also a 40 MHz version, the '''2205-40'''. | ||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | 20 MHz }} | |||
{{Spec | CRT | 1.8 kV cathode voltage, no post-deflection acceleration }} | |||
{{Spec | Weight | 6.2 kg (13.7 lb) }} | |||
{{Spec | Power | max. 40 W }} | |||
{{EndSpecs}} | |||
''please expand'' | |||
==Prices== | |||
* 1990: $695 (~$1,600 in 2023 dollars) | |||
==Internals== | |||
Each of the two inputs first goes through attenuators, then discrete dual-JFET source-follower buffer stage, then an Intersil CA3102 differential amplifier chip to provide some gain and convert from single-ended to a differential signal. | |||
The vertical output amplifier driving the CRT is discrete and has an interesting design that conserves power (and minimizes heat). | |||
When the output is slewing at low rates, the output transistors have a constant, relatively low current passing through them. | |||
At higher slew rates, to provide enough current to charge and discharge the parasitic and CRT plate capacitances, the output stage operates in more of a push-pull mode. | |||
The 2205 has a switch-mode power supply that produces low voltage and CRT voltages using transformer T901, which operates at about 60 kHz. | |||
Interestingly, there is a also a mains-frequency step-down and isolation transformer (T901) in the power path before the SMPS. | |||
==Pictures== | ==Pictures== |
Latest revision as of 03:54, 8 January 2024
The Tektronix 2205 is a 20 MHz dual-trace analog oscilloscope introduced in 1989. There is a also a 40 MHz version, the 2205-40.
Key Specifications
Bandwidth | 20 MHz |
---|---|
CRT | 1.8 kV cathode voltage, no post-deflection acceleration |
Weight | 6.2 kg (13.7 lb) |
Power | max. 40 W |
please expand
Prices
- 1990: $695 (~$1,600 in 2023 dollars)
Internals
Each of the two inputs first goes through attenuators, then discrete dual-JFET source-follower buffer stage, then an Intersil CA3102 differential amplifier chip to provide some gain and convert from single-ended to a differential signal.
The vertical output amplifier driving the CRT is discrete and has an interesting design that conserves power (and minimizes heat). When the output is slewing at low rates, the output transistors have a constant, relatively low current passing through them. At higher slew rates, to provide enough current to charge and discharge the parasitic and CRT plate capacitances, the output stage operates in more of a push-pull mode.
The 2205 has a switch-mode power supply that produces low voltage and CRT voltages using transformer T901, which operates at about 60 kHz. Interestingly, there is a also a mains-frequency step-down and isolation transformer (T901) in the power path before the SMPS.
Pictures
-
-
-
-
-
-
-
-
-
-
-
-
-
2205-40
-
2205-40
-
2205-40
-
2205-40
-
2205-40
-
2205-40
-
2205-40
-
2205-40