2467: Difference between revisions

1,442 bytes added ,  29 January
no edit summary
(Removed redirect to 2465A)
Tag: Removed redirect
No edit summary
(9 intermediate revisions by 3 users not shown)
Line 10: Line 10:
|designers=Art Metz; Ken Schlotzhauer; Walt Ainsworth
|designers=Art Metz; Ken Schlotzhauer; Walt Ainsworth
|manuals=
|manuals=
* [[Media:050-2180-06.pdf|24x5A/2467 Firmware Release Notes]]
==2467==
* [[Media:070-5857-00.pdf|24x5A Options Service]] (OCR PDF, 26M)
* [[Media:070-5854-00.pdf|2467 Operators Manual 070-5854-00]]
* [[Media:070-6014-00.pdf|24x5A Operator]]
* [[Media:070-5857-00.pdf|24x5A/2467 Options Service 070-5857-00]] (OCR)
* [[Media:070-6017-00.pdf|2455A/2445A Service]] (OCR PDF, 20M)
* [[Media:070-6019-01.pdf|2465A/2467 Service Manual 070-6019-01]] (OCR)
* [[Media:070-6019-01.pdf|2465A/2467 Service]] (OCR PDF, 29M)
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit 070-6291-00]]
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit (PDF, needs OCR)]]
* [[Media:050-2180-06.pdf|24x5A/2467 Firmware Release Notes 050-2180-06]]
 
==2467B==
* [[Media:070-6861-01.pdf|Tek 2467B Oscilloscope and Options Operators Manual 070-6861-01]]
* [[Media:070-6861-02.pdf|Tek 2467B Oscilloscope and Options Operators Manual 070-6861-02]]
* [[Media:070-6863-00.pdf|Tektronix 2465B/2467B Service Manual 070-6863-00]]
* [[Media:070-6863-01.pdf|Tektronix 2465B/2467B Service Manual 070-6863-01]]
* [[Media:070-6864-02.pdf|Tek 24X5B 2467B Options Service Manual 070-6864-02]]
* [[Media:24xxB_Catalog_Pages.pdf|24xxB Catalog Pages]]
* [[Media:2467B option 06 to 09 upgrade.pdf|2467B - Upgrading option 06 to option 09]]
}}
}}
The '''2467''' and '''2467B''' are the same as the [[2465A]], except that the 2465A uses a conventional CRT while the 2467 and 2467B use a [[micro-channel plate CRT]] that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.
The '''2467''' and '''2467B''' are the same as the [[2465A]], except that the 2465A uses a conventional CRT while the 2467 and 2467B use a [[micro-channel plate CRT]] that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.<br>
The '''2567BHD''' variant is identical to the 2467B with the addition of Options 5H and 06 included.


The 2467 is from the penultimate generation of analog Tektronix scopes.
The 2467 is from the penultimate generation of analog Tektronix scopes.


The horizontal amplifier was designed by [[Art Metz]] and [[Ken Schlotzhauer]]. Art Metz also worked on the triggers. Art Metz and [[Walt Ainsworth]] designed the sweeps.
The horizontal amplifier was designed by [[Art Metz]] and [[Ken Schlotzhauer]]. Art Metz also worked on the triggers. Art Metz and [[Walt Ainsworth]] designed the sweeps.
'''Options'''
* Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
* Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
* Option 10 added a [[GPIB interface]] for remote control.
* Option 11 added two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument.  Only shown in the 1987 catalogue.


{{BeginSpecs}}
{{BeginSpecs}}
Line 43: Line 45:
{{EndSpecs}}
{{EndSpecs}}


==See also==
==ROM Images==
* [[2465]]
* [[Media:2467_U2160_160-3302-06.zip|160-3302-06]](ZIP)
* [[2465B]]
* [[Media:2467_U2260_160-3303-06.zip|160-3303-06]](ZIP)
* [[2445 PSU Repairs|PSU Repairs]]
 
* [[Media:160-3302-09.bin|160-3302-09.bin]]
* [[Media:160-3303-09.bin|160-3303-09.bin]]
 
==Options==
* Option 01 - (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 05 - (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
* Option 05H - High-definition Television (As above but supports HDTV) - 2467B only
* Option 06 - (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 09 - Add option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
* Option 10 - Add a [[GPIB interface]] for remote control.
* Option 11 - Add two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument.  Only shown in the 1987 catalogue.
* Option 1R - Shipped with a 19" rack mount kit fitted.
* For accessories, see [[2467/Accessories]].
 
==Gerbers==
* [[Media:2467B_Flex_PCB_gerber.zip|Front panel flex PCB gerber files]]
 
==Links==
* [https://www.youtube.com/watch?v=v9KaTgChudw Tektronix 2467B "Bright Eye (tm)" Oscilloscope – 1992 Tek sales video] by vintageTek Museum @ YouTube
* [https://www.youtube.com/watch?v=NjHbfbtNhyY Tektronix 2467B Oscilloscope Restoration] by NFM @ YouTube
* See also [[2465]], [[2465B]], [[2445 PSU Repairs|PSU Repairs]]
{{Documents|Link=2467}}


==Pictures==
==Pictures==
Line 53: Line 77:
Tek 2467 rear.jpg
Tek 2467 rear.jpg
</gallery>
</gallery>
{{Parts|2467}}
{{Parts|2467B}}




[[Category:246x series scopes]]
[[Category:246x series scopes]]
[[Category:Introduced in 1986]]
[[Category:Micro-channel plate CRTs]]
[[Category:Micro-channel plate CRTs]]