106: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
(19 intermediate revisions by 6 users not shown)
Line 1: Line 1:
[[File:Tek 106 front2.jpg | thumb | right | 300px]]
{{Instrument Sidebar
|manufacturer=Tektronix
|model=106
|class=Pulse generator
|series=
|summary=Pulse generator
|image=Tek 106 front2.jpg
|caption=Tektronix 106
|introduced=1966
|discontinued=(?)
|designers=Bill Lukens
|manuals=
* [[Media:070-0523-00.pdf|Tektronix 106 Manual]]
* [[Media:Tek 106 irb.pdf|Tektronix 106 Instrument Reference Book]]
* [[Media:Tek 106 design notes.pdf|Possible Tek 106 Design Notes]]
* [[Media:Tek 106 fcp jan 1967.pdf|Tektronix 106 Factory Calibration Procedure, January 1967]]
* [[Media:Tek 106 fcp june 1969.pdf|Tektronix 106 Factory Calibration Procedure, June 1969‎]]
}}
The '''Tektronix Type 106''' is a square-wave generator [[introduced in 1966]].  It has four outputs:
The '''Tektronix Type 106''' is a square-wave generator [[introduced in 1966]].  It has four outputs:


* '''Fast Rise +Output:''' 500 mV into 50 Ω load, positive-going pulse, 1 ns rise time, 50 Ω output impedance, [[GR-874 connector]]
* '''Fast Rise +Output:''' 500 mV into 50 Ω load, positive-going pulse, 1 ns rise time, 50 Ω output impedance, [[GR-874 connector]]
* '''Fast Rise -Output:''' 500 mV into 50 Ω load, negative-going pulse, 1 ns rise time, 50 Ω output impedance, GR-874 connector
* '''Fast Rise −Output:''' 500 mV into 50 Ω load, negative-going pulse, 1 ns rise time, 50 Ω output impedance, GR-874 connector
* '''High Amplitude Output:''' 12 V into 50 Ω load, 12 ns rise time, 600 Ω output impedance, GR-874 connector
* '''High Amplitude Output:''' 12 V into 50 Ω load, 12 ns rise time, 600 Ω output impedance, GR-874 connector
* '''Trigger Output:''' 100 mV into 50 Ω load, 50 ns rise time, 150 Ω output impedance, [[BNC connector]]
* '''Trigger Output:''' 100 mV into 50 Ω load, 50 ns rise time, 150 Ω output impedance, [[BNC connector]]


The 1 ns rise-time outputs are generated using diodes to clip a high  
The 1 ns rise-time outputs are generated using diodes to clip a high amplitude signal. In units with serial numbers less than 1190, GaAs diodes were used for clipping.   
amplitude signal. In units with serial numbers less than 1190, GaAs diodes  
After serial number 1190, silicon diodes were used.
were used for clipping.  After serial number 1190, silicon diodes were used.


The high amplitude output stage of the 106 is made of four [[7189|7189A]] tubes in parallel.   
The high amplitude output stage of the 106 is made of four [[7189A]] tubes in parallel.   
With moderate effort, the socket wiring can be made compatible with the [[7189]] aka [[6BQ5]].
With moderate effort, the socket wiring can be made compatible with the [[7189]] and [[6BQ5]].


==Manuals==
==Links==
* [http://w140.com/tek_106.pdf Tektronix 106 Manual (PDF)]
* [https://www.youtube.com/watch?v=8RCoTXdgZts Type 106 Rebuild] by Zenwizard Studios @ YouTube
* [http://w140.com/106.djvu Tektronix 106 Manual (DjVu)]
* [https://www.youtube.com/watch?v=ZmOtKnk-oGY Type 106 Power Supply Specific Information] by Zenwizard Studios @ YouTube
{{Documents|Link=106}}
{{PatentLinks|106}}


==Pictures==
==Pictures==
Line 22: Line 40:
Tek 106 front.jpg|Front
Tek 106 front.jpg|Front
Tek 106 front2.jpg
Tek 106 front2.jpg
Tek106-outputs.jpg | Outputs
Tek 106 rear.jpg|Rear
Tek 106 rear.jpg|Rear
106 sch.png|Schematic
106 sch.png|Schematic
Line 28: Line 47:
Tek 106 rise.jpg|106 pulse on [[567]] with [[S4]] measuring 600 ps risetime
Tek 106 rise.jpg|106 pulse on [[567]] with [[S4]] measuring 600 ps risetime
Tek 106 ps.jpg
Tek 106 ps.jpg
Tek106-power-supply-with-refdes.jpg|Power Supply with Component Locations
Tek 106 thermalswitch.jpg
Tek 106 thermalswitch.jpg
Tek 106 clipperdiodes.jpg
Tek 106 clipperdiodes.jpg
Line 37: Line 57:


[[Category:Pulse generators]]
[[Category:Pulse generators]]
[[Category:Introduced in 1966]]
[[Category:GR874]]

Revision as of 01:41, 9 July 2024

Tektronix 106
Pulse generator
Tektronix 106

Produced from 1966 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix Type 106 is a square-wave generator introduced in 1966. It has four outputs:

  • Fast Rise +Output: 500 mV into 50 Ω load, positive-going pulse, 1 ns rise time, 50 Ω output impedance, GR-874 connector
  • Fast Rise −Output: 500 mV into 50 Ω load, negative-going pulse, 1 ns rise time, 50 Ω output impedance, GR-874 connector
  • High Amplitude Output: 12 V into 50 Ω load, 12 ns rise time, 600 Ω output impedance, GR-874 connector
  • Trigger Output: 100 mV into 50 Ω load, 50 ns rise time, 150 Ω output impedance, BNC connector

The 1 ns rise-time outputs are generated using diodes to clip a high amplitude signal. In units with serial numbers less than 1190, GaAs diodes were used for clipping. After serial number 1190, silicon diodes were used.

The high amplitude output stage of the 106 is made of four 7189A tubes in parallel. With moderate effort, the socket wiring can be made compatible with the 7189 and 6BQ5.

Links

Documents Referencing 106

Document Class Title Authors Year Links
Tekscope 1970 V2 N3 Jun 1970.pdf Article Tektronix Signal Sources 1970

Pictures