R116: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(One intermediate revision by one other user not shown) | |||
Line 5: | Line 5: | ||
|series= | |series= | ||
|summary=Programmable pulse generator | |summary=Programmable pulse generator | ||
|image= | |image=R116-FrontFull.jpg | ||
|caption=Tek R116 | |caption=Tek R116 | ||
|introduced=1965 | |introduced=1965 | ||
Line 11: | Line 11: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:070-0498-00.pdf|Tektronix R116 Manual]] (early | * [[Media:070-0498-00.pdf|Tektronix R116 Manual]] (early) | ||
* [[Media:070-1042-00.pdf|Tektronix R116 Manual]] (late | * [[Media:070-1042-00.pdf|Tektronix R116 Manual]] (late) | ||
* [https://w140.com/tek_r116_sn1211_changes.pdf Tektronix R116 Manual Changes at Serial Number 1121 | * [https://w140.com/tek_r116_sn1211_changes.pdf Tektronix R116 Manual Changes at Serial Number 1121] | ||
* [https://w140.com/tek_r116_1968_catalog.pdf Tektronix R116 in 1968 Catalog | * [https://w140.com/tek_r116_1968_catalog.pdf Tektronix R116 in 1968 Catalog] | ||
* [https://w140.com/tek_r116_description.pdf Description of R116 from Tektronix Automated Testing Systems book | * [https://w140.com/tek_r116_description.pdf Description of R116 from Tektronix Automated Testing Systems book] | ||
* [[Media:Tek r116 fcp jan 1968.pdf|Tektronix R116 Factory Calibration Procedure January 1968 | * [[Media:Tek r116 fcp jan 1968.pdf|Tektronix R116 Factory Calibration Procedure January 1968]] | ||
* [[Media:Tek r116 fcp.pdf|Tektronix R116 Factory Calibration Procedure June 1968]] | * [[Media:Tek r116 fcp.pdf|Tektronix R116 Factory Calibration Procedure June 1968]] | ||
}} | }} | ||
Line 26: | Line 26: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Pulse period | 100 ns to 11 ms ( | {{Spec | Pulse period | 100 ns to 11 ms (±3%)}} | ||
{{Spec | Pulse delay | {{Spec | Pulse delay | 50 ns to 550 μs (±3% + 10 ns)}} | ||
{{Spec | Pulse width | {{Spec | Pulse width | 50 ns to 550 μs (±3% + 10 ns)}} | ||
{{Spec | Rise time | {{Spec | Rise time | 10 ns to 110 μs (±10% below in 1 ns and 10 ns ranges, ± 5% above)}} | ||
{{Spec | Fall time | {{Spec | Fall time | 10 ns to 110 μs (±10% below in 1 ns and 10 ns ranges, ± 5% above)}} | ||
{{Spec | Pulse amplitude | 0.4 V to 10 V into 50 Ω, positive or negative ( | {{Spec | Pulse amplitude | 0.4 V to 10 V into 50 Ω, positive or negative (±3% + 15/25/50 mV) }} | ||
{{Spec | Pulse offset | 0 to ±5 V in 3 ranges ( | {{Spec | Pulse offset | 0 to ±5 V in 3 ranges (±5% + 200 mV)}} | ||
{{Spec | Features | | {{Spec | Features | | ||
* "Programmable" | * "Programmable" | ||
* Double pulse mode | * Double pulse mode | ||
Line 60: | Line 60: | ||
==Links== | ==Links== | ||
{{Documents|Link=R116}} | {{Documents|Link=R116}} | ||
{{PatentLinks|R116}} | |||
==Pictures== | ==Pictures== | ||
Line 77: | Line 78: | ||
Tek r116 internal 2.jpg | Tek r116 internal 2.jpg | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|R116}} | |||
[[Category:Pulse generators]] | [[Category:Pulse generators]] |
Latest revision as of 05:04, 17 September 2024
The Tektronix R116 is a programmable pulse generator introduced in 1965 for use with automated measurement systems such as the 240 and R250.
A modified version (R116 MOD703L) was part of the S-3130 testing system.
The R116 uses a 1N3716 tunnel diode to produce pulses.
Key Specifications
Pulse period | 100 ns to 11 ms (±3%) |
---|---|
Pulse delay | 50 ns to 550 μs (±3% + 10 ns) |
Pulse width | 50 ns to 550 μs (±3% + 10 ns) |
Rise time | 10 ns to 110 μs (±10% below in 1 ns and 10 ns ranges, ± 5% above) |
Fall time | 10 ns to 110 μs (±10% below in 1 ns and 10 ns ranges, ± 5% above) |
Pulse amplitude | 0.4 V to 10 V into 50 Ω, positive or negative (±3% + 15/25/50 mV) |
Pulse offset | 0 to ±5 V in 3 ranges (±5% + 200 mV) |
Features |
|
The R116 has a programming connector in the back. Eight operating parameters can be programmed digitally (by switch closure):
- Trigger Source
- Mode
- Period Range
- Delay or Burst Time Range
- Width Range
- Amplitude Range
- Polarity
- Rise Time/Fall Time Range
Seven more parameters are controlled by connecting external resistances:
- Period Multiplier
- Delay or Burst Time Multiplier
- Width Multiplier
- Amplitude Multiplier
- DC Offset
- Rise Time Multiplier
- Fall Time Multiplier
Links
Documents Referencing R116
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1970 V2 N3 Jun 1970.pdf | Article | Tektronix Signal Sources | 1970 | 2101 • 2901 • 114 • 115 • R116 • 106 • 191 • 284 • 140 |
Pictures
Components
Some Parts Used in the R116
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
1N3716 | 152-093 • 152-0093-00 | Discrete component | 4.7 mA / 50 pF tunnel diode | 3B3 • R116 |