[[File:Tek_191_front.jpg|350px|thumb|right|Tektronix 191]]
{{Instrument Sidebar
The '''Tektronix Type 191 Constant Amplitude Signal Generator''' is a sine wave source
|manufacturer=Tektronix
[[introduced in 1966]].
|model=191
|class=Signal generator
|series=
|summary=Constant-amplitude signal generator
|image=Tek 191 front.jpg
|caption=Tektronix 191 front
|introduced=1966
|discontinued=(?)
|designers=John Mulvey;
|manuals=
* [[Media:070-0522-00.pdf|Tektronix 191 Manual]]
* [[Media:TB-9-6625-2176-35.pdf|TB-9-6625-2176-35 - 191 calibration]]
* [[Media:Tek 191 fcp june 1966.pdf‎|Tektronix 191 Factory Calibration Procedure, June 1966]]
}}
The '''Tektronix Type 191 Constant Amplitude Signal Generator''' is a sine wave source [[introduced in 1966]] to replace the earlier [[067-506]].


{{MissingSpecs}}
It produces a sine output from 350 kHz to 100 MHz in seven bands whose amplitude remains constant as the frequency is varied, provided the load limitations of the instrument are not exceeded.
The output amplitude can be adjusted in calibrated steps from 5 mV to 5 V in three ranges.


The 191 covers frequencies from 350 kHz to 100 MHz in seven bands. The output
{{BeginSpecs}}
amplitude can be adjusted in calibrated steps from 5 mV to 5 V in three ranges
{{Spec | Output impedance    | 50 Ω }}
{{Spec | Amplitude range      | 5–50 mV, 50-500 mV, 0.5-5 V<sub>p-p</sub> }}
{{Spec | Amplitude accuracy  | At 50 kHz into a 50 Ω load: ±3% for 0.5–5 V range; ±4% for 50–500 mV range; ±5% for 5–50 mV range }}
{{Spec | Amplitude regulation | ±3% for 5 mV to 5.5 V into 50 Ω at 50 KHz; +3%/-5% for 5 mV and 55 mV ranges or frequency >42 MHz }}
{{Spec | Frequency range      | 350 kHz – 100 MHz }}
{{Spec | Frequency accuracy  | Within ±2% of the selected frequency when the output is terminated with 50 Ω }}
{{Spec | Harmonic content    | Typically less than 5% }}
{{EndSpecs}}
 
==Links==
{{Documents|Link=191}}
{{PatentLinks|191}}


==Internals==
==Internals==
Line 16: Line 42:


The calibration procedure in the manual makes use of a [[661]] to accurately view the output waveform.
The calibration procedure in the manual makes use of a [[661]] to accurately view the output waveform.
==Manuals==
* [http://w140.com/mmm/tek-191.pdf Tektronix 191 Manual (PDF)]
* [[Media:TB-9-6625-2176-35.pdf|TB-9-6625-2176-35 - 191 calibration]]
* [[Media:Tek 191 fcp june 1966.pdf‎]]


==Pictures==
==Pictures==
Line 33: Line 54:
</gallery>
</gallery>


[[Category:Signal generators]]
==Components==
[[Category:Introduced in 1966]]
{{Parts|191}}
 
[[Category:Signal generators]]  
[[Category:GR874]]
[[Category:GR874]]

Latest revision as of 04:47, 16 October 2024

Tektronix 191
Constant-amplitude signal generator
Tektronix 191 front

Produced from 1966 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix Type 191 Constant Amplitude Signal Generator is a sine wave source introduced in 1966 to replace the earlier 067-506.

It produces a sine output from 350 kHz to 100 MHz in seven bands whose amplitude remains constant as the frequency is varied, provided the load limitations of the instrument are not exceeded. The output amplitude can be adjusted in calibrated steps from 5 mV to 5 V in three ranges.

Key Specifications

Output impedance 50 Ω
Amplitude range 5–50 mV, 50-500 mV, 0.5-5 Vp-p
Amplitude accuracy At 50 kHz into a 50 Ω load: ±3% for 0.5–5 V range; ±4% for 50–500 mV range; ±5% for 5–50 mV range
Amplitude regulation ±3% for 5 mV to 5.5 V into 50 Ω at 50 KHz; +3%/-5% for 5 mV and 55 mV ranges or frequency >42 MHz
Frequency range 350 kHz – 100 MHz
Frequency accuracy Within ±2% of the selected frequency when the output is terminated with 50 Ω
Harmonic content Typically less than 5%

Links

Documents Referencing 191

Document Class Title Authors Year Links
Tekscope 1970 V2 N3 Jun 1970.pdf Article Tektronix Signal Sources 1970

Internals

The oscillator is a Colpitts oscillator using a 7119 tube.

A peak-to-peak detector made with two GaAs diodes measures the swing of the oscillator and produces a DC feedback signal that controls a series voltage regulator that supplies power to the oscillator.

The calibration procedure in the manual makes use of a 661 to accurately view the output waveform.

Pictures

Components

Some Parts Used in the 191

Part Part Number(s) Class Description Used in
7119 154-0340-00 Vacuum Tube (Dual Triode) dual triode 067-506 067-0532-00 191 3A3 3B4 3B5 516 545B 549 661 Chemtrix 205