P6000: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
(space added) |
||
(9 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
[[ | {{Probe Sidebar | ||
The '''Tektronix P6000''' is a 30 MHz, ×10 passive voltage probe designed for use with | |manufacturer=Tektronix | ||
oscilloscopes that have a 1 MΩ // 20 to 50 pF input impedance and a [[UHF connector]]. | |model=P6000 | ||
|summary=30 MHz ×10 Passive Probe | |||
|image=Tektronix_P6000_Probe_2.jpg | |||
|caption=Tektronix P6000 | |||
|for=1 MΩ scope inputs | |||
|series= | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:Tek_p6000_old.pdf|Tektronix P6000 Manual]] (older) | |||
* [[Media:Tek_p6000_new.pdf|Tektronix P6000 Manual]] (newer) | |||
* [[Media:Tek_p6000-to-p6005_parts.pdf|Tek P6000 to P6005 Parts]] | |||
}} | |||
The '''Tektronix P6000''' is a 30 MHz, ×10 passive voltage probe designed for use with oscilloscopes that have a 1 MΩ // 20 to 50 pF input impedance and a [[UHF connector]]. | |||
The [[P6003]] is a variant of the [[P6000]] that has a [[BNC connector]] instead of a UHF connector. | |||
The compensation is done by changing the length of the probe body itself, which is achieved by turning the front part after loosening the finger stop which also serves as a twist-lock. | |||
{{BeginSpecs}} | |||
Maximum | {{Spec | Input impedance | 10 MΩ // 11.5–14.5 pF }} | ||
{{Spec | Compensation range | 1 MΩ // 20–50 pF }} | |||
{{Spec | Maximum input | 1200 V DC or AC peak}} | |||
{{Spec | Cable | | |||
* 3.5 feet, part number 010-0020-00 | * 3.5 feet, part number 010-0020-00 | ||
* 6 feet, part number 010-0030-00 | * 6 feet, part number 010-0030-00 | ||
* 9 feet, part number 010-0035-00 | * 9 feet, part number 010-0035-00 | ||
* 12 feet, part number 010-0041-00 | * 12 feet, part number 010-0041-00 | ||
}} | |||
{{EndSpecs}} | |||
== | ==Pictures== | ||
<gallery> | |||
Tektronix_P6000_Probe_2.jpg | |||
Tektronix_P6000_probe.jpg | |||
Tektronix_P6000_head.jpg | |||
Tektronix_P6000_head_2.jpg | |||
Tektronix P6000 compensation.JPG | |||
Tektronix_P6000_UHF_connector.jpg | |||
</gallery> | |||
[[Category:1 | [[Category:1 MΩ Oscilloscope probes]] | ||
[[Category:6-32 probes]] |
Latest revision as of 00:13, 4 July 2023
The Tektronix P6000 is a 30 MHz, ×10 passive voltage probe designed for use with oscilloscopes that have a 1 MΩ // 20 to 50 pF input impedance and a UHF connector. The P6003 is a variant of the P6000 that has a BNC connector instead of a UHF connector. The compensation is done by changing the length of the probe body itself, which is achieved by turning the front part after loosening the finger stop which also serves as a twist-lock.
Key Specifications
Input impedance | 10 MΩ // 11.5–14.5 pF |
---|---|
Compensation range | 1 MΩ // 20–50 pF |
Maximum input | 1200 V DC or AC peak |
Cable |
|