P6205: Difference between revisions
No edit summary |
|||
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{Probe Sidebar | |||
|manufacturer=Tektronix | |||
|model=P6205 | |||
|summary=750 MHz active probe | |||
|for=Tekprobe BNC connector | |||
|image=P6205.jpg | |||
|caption=Tektronix P6205 | |||
|introduced=1991 | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:070-8202-01.pdf|Tektronix P6205 Manual]] | |||
* [[Media:Tek-p6203-p62204-p62205-p6217-p6231.pdf|Tektronix P6203, P6204, P6205, P6217, P6231 Catalog Specs]] | |||
}} | |||
The '''Tektronix P6205''' is a 750 MHz active FET probe for [[TDS500]] series, [[DSA600]] series, [[CSA404]] and [[11000-series scopes]] with [[Tekprobe BNC connector|Tekprobe BNC inputs]]. | The '''Tektronix P6205''' is a 750 MHz active FET probe for [[TDS500]] series, [[DSA600]] series, [[CSA404]] and [[11000-series scopes]] with [[Tekprobe BNC connector|Tekprobe BNC inputs]]. | ||
Line 12: | Line 24: | ||
{{Spec | Interface | [[Tekprobe BNC connector]] }} | {{Spec | Interface | [[Tekprobe BNC connector]] }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
P6205_exploded.jpg | Exploded view of the probe assembly. The PCB is soldered to the shielding tube and the coax, and the tube is then crimped over the coax. | P6205_exploded.jpg | Exploded view of the probe assembly. The PCB is soldered to the shielding tube and the coax, and the tube is then crimped over the coax. | ||
P6205_%27scope_side.jpg | The probe uses "lossless" | P6205_%27scope_side.jpg | The probe uses "lossless" 50 Ω coax, as there's amplification at the business end. The circuitry connects to the TekProbe interface to declare the probe's identity to the scope. | ||
P6205-int-1.jpg | The tip network comprises three laser-trimmed resistors and a laser-trimmed capacitor. The tip resistance measures | P6205-int-1.jpg | The tip network comprises three laser-trimmed resistors and a laser-trimmed capacitor. The tip resistance measures 800 kΩ, the middle resistor was on the order of 25 Ω, and the resistance to ground is 200 kΩ. This makes a 1/5 divider from tip to the amplifier. | ||
P6205-int-2.jpg | P6205-int-2.jpg | ||
P6205-int-3.jpg | P6205-int-3.jpg | ||
P6205-int-4.jpg | It looks like the amplifier has two identical sections, presumably the same chip is used for differential active probes. | P6205-int-4.jpg | It looks like the amplifier has two identical sections, presumably the same chip is used for differential active probes. | ||
</gallery | </gallery> | ||
[[Category:Active | [[Category:Active oscilloscope probes]] | ||
[[Category:Tekprobe BNC]] | [[Category:Tekprobe BNC]] |
Latest revision as of 09:08, 21 July 2022
The Tektronix P6205 is a 750 MHz active FET probe for TDS500 series, DSA600 series, CSA404 and 11000-series scopes with Tekprobe BNC inputs.
Key Specifications
Bandwidth | 750 MHz (probe only) 600 MHz on 11A72 450 MHz on TDS500/600 |
---|---|
Rise time | < 467 ps |
Attenuation | 10× |
Input impedance | 1 MΩ // 2 pF |
Output | into 50 Ω |
Dynamic range | ±10 V |
Max. input voltage | 40 V DC + peak AC non-destructive |
Interface | Tekprobe BNC connector |
Pictures
-
Exploded view of the probe assembly. The PCB is soldered to the shielding tube and the coax, and the tube is then crimped over the coax.
-
The probe uses "lossless" 50 Ω coax, as there's amplification at the business end. The circuitry connects to the TekProbe interface to declare the probe's identity to the scope.
-
The tip network comprises three laser-trimmed resistors and a laser-trimmed capacitor. The tip resistance measures 800 kΩ, the middle resistor was on the order of 25 Ω, and the resistance to ground is 200 kΩ. This makes a 1/5 divider from tip to the amplifier.
-
-
-
It looks like the amplifier has two identical sections, presumably the same chip is used for differential active probes.